Comparison of the effects of ophthalmic solutions on human corneal epithelial cells using fluorescent dyes.

J Ocul Pharmacol Ther

1 School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada .

Published: November 2013

Purpose: To investigate the effect of differently preserved ophthalmic solutions on the viability and barrier function of human corneal epithelial cells (HCEC) using fluorescent dyes.

Methods: HCEC monolayers were exposed to the ophthalmic solutions containing benzalkonium chloride (BAK), edetate disodium, polyquad, stabilized oxychloro complex (Purite), sodium perborate, or sorbic acid for 5 min, 15 min, and 1 h. At 24 h after exposure, the cultures were assessed for metabolic activity using alamarBlue. The enzyme activity, membrane integrity, and apoptosis were evaluated using confocal microscopy. Barrier function was assessed using sodium fluorescein.

Results: The metabolic assay showed that the BAK-preserved ophthalmic solutions significantly reduced cell viability after a 5-min exposure compared to the phosphate buffered saline treated control (P<0.05). Using confocal microscopy, the micrographs showed that BAK caused a reduction in the enzyme activity, increased membrane permeability, and decreased the number of viable cells. Ophthalmic solutions with new preservatives had varying time-dependent adverse effects on cell viability, and the preservative-free solution had the least effect on HCEC. Sodium fluorescein permeability showed that HCEC monolayers treated with BAK-preserved solutions were more permeable to sodium fluorescein than those treated by the other ophthalmic solutions (P<0.05).

Conclusions: BAK-preserved solutions had greater adverse effects on metabolic activity, enzyme activity, membrane integrity, cell viability, and barrier function than the solutions that were not preserved with BAK. Our study suggests that BAK-free especially, preservative-free ophthalmic solutions are safer alternatives to BAK-preserved ones.

Download full-text PDF

Source
http://dx.doi.org/10.1089/jop.2013.0002DOI Listing

Publication Analysis

Top Keywords

ophthalmic solutions
16
human corneal
8
corneal epithelial
8
epithelial cells
8
barrier function
8
comparison effects
4
ophthalmic
4
effects ophthalmic
4
solutions
4
solutions human
4

Similar Publications

Refractive surgery, which includes techniques such as Laser-Assisted In Situ Keratomileusis (LASIK), Photorefractive Keratectomy (PRK) and Small Incision Lenticule Extraction (SMILE), has revolutionized ophthalmology by offering advanced solutions for vision correction. However, the choice of the technique to be used in the individual patient is highly dependent on a thorough preoperative evaluation. This retrospective study aims to investigate how preoperative parameters, including corneal thickness, topography, and refraction, affect long-term post-operative clinical outcomes.

View Article and Find Full Text PDF

Purpose: To investigate the effect of average intraocular pressure (IOP) on the true rate of glaucoma progression (RoP) in the United Kingdom Glaucoma Treatment Study (UKGTS).

Methods: UKGTS participants were randomized to placebo or Latanoprost drops and monitored for up to two years with visual field tests (VF, 24-2 SITA standard), IOP measurements, and optic nerve imaging. We included eyes with at least three structural or functional assessments (VF with <15% false-positive errors).

View Article and Find Full Text PDF

: Diabetes is a well-recognised factor inducing a plethora of corneal alterations ranging from dry eye to reduced corneal sensibility, epithelial defects, and reduced cicatrisation. This cohort study aimed to assess the efficacy of a novel ophthalmic solution combining cross-linked hyaluronic acid (CHA), chondroitin sulfate (CS), and inositol (INS) in managing diabetes-induced corneal alterations. Specifically, it evaluated the solution's impact on the tear breakup time (TBUT), the ocular surface disease index (OSDI), and corneal sensitivity after three months of treatment.

View Article and Find Full Text PDF

Purpose: To evaluate dynamic changes in ciliary parameters and Implantable Collamer Lens V4C (ICL) (STAAR Surgical) haptic position using mydriatic and miotic agents and their effects on the central and peripheral vault.

Methods: This study involved 80 eyes from 40 consecutive patients (mean age: 28.05 years; range: 19 to 42 years) examined 3 months after ICL implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!