The use of compliance chambers in mock circulatory loop construction is the predominant means of simulating arterial compliance. Utilizing mock circulatory loops as bench test methods for cardiac assist technologies necessitates that they must be capable of reproducing the circulatory conditions that would exist physiologically. Of particular interest is the ability to determine instantaneous compliance of the system, and the ability to change the compliance in real-time. This capability enables continuous battery testing of conditions without stopping the flow to change the compliance chamber settings, and the simulation of dynamic changes in arterial compliance. The method tested involves the use of a compliance chamber utilizing a circular natural latex rubber membrane separating the fluid and air portions of the device. Change in system compliance is affected by the airspace pressure, which creates more reaction force at the membrane to the fluid pressure. A pressure sensor in the fluid portion of the chamber and a displacement sensor monitoring membrane center deflection allow for real-time inputs to the control algorithm. A predefined numerical model correlates the displacement sensor data to the volume displacement of the membrane. The control algorithm involves a tuned π loop maintaining the volume distention of the membrane via regulation of the air space pressure. The proportional integral (PI) controller tuning was achieved by creating a computational model of the compliance chamber using Simulink™ Simscape toolboxes. These toolboxes were used to construct a model of the hydraulic, mechanical, and pneumatic elements in the physical design. Parameter Estimation™ tools and Design Optimization™ methods were employed to determine unknown physical parameters in the system, and tune the process controller used to maintain the compliance setting. It was found that the resulting control architecture was capable of maintaining compliance along a pressure-volume curve and allowed for changes to the compliance set point curve without stopping the pulsatile flow.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3707194PMC
http://dx.doi.org/10.1115/1.4007943DOI Listing

Publication Analysis

Top Keywords

compliance chamber
16
compliance
13
mock circulatory
12
circulatory loop
8
arterial compliance
8
change compliance
8
displacement sensor
8
control algorithm
8
chamber
5
membrane
5

Similar Publications

Introduction: Anterior cruciate ligament (ACL) reconstruction (ACLR) is the gold standard for treating ACL injuries, particularly in soccer players who are at a high risk of knee injury. While professional athletes often return to sport (RTS) within 7-10 months after ACLR, non-elite players experience significant delays. There is a need to investigate neuromuscular deficits and functional asymmetries in the non-elite group, which may persist even after clearance for RTS.

View Article and Find Full Text PDF

Walking on compliant terrains, like carpets, grass, and soil, presents a unique challenge, especially for individuals with mobility impairments. In contrast to rigid-ground walking, compliant surfaces alter movement dynamics and increase the risk of falls. Understanding and modeling gait control across such soft and deformable surfaces is thus crucial for maintaining daily mobility.

View Article and Find Full Text PDF

Diaphragmatic rupture during labor is an exceptionally rare condition, with a limited number of cases reported in the literature. A recent review underscores the rarity of this complication and emphasizes the associated challenges in diagnosis and management. This case report presents a postpartum diaphragmatic rupture, focusing on the diagnostic and therapeutic challenges it poses, particularly in the context of unsupervised deliveries.

View Article and Find Full Text PDF

Endodontics, a branch of dentistry, treats diseases and impairments in tissues within and surrounding the natural teeth. The aim of the study was to analyze the publication trends and key features of endodontic research published over the past 20 years across the globe. The quantitative bibliometric research approach was used to extract the data from the Web of Science database.

View Article and Find Full Text PDF

Background: This study aimed to identify the clinical characteristics of cases that is related to the response rate of adalimumab (ADA) treatment.

Methods: A retrospective review of medical records was conducted for pediatric patients with non-infectious uveitis undergoing ADA treatment for a minimum of six months. The patients were stratified into two groups: those with anterior segment inflammation (ASI+) and those without anterior segment inflammation (ASI-).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!