Purpose: This study aims to: (1) measure the shear modulus of nucleus pulposus (NP) in intact human vertebra-disc-vertebra segments using a magnetic resonance elastography setup for a 7T whole-body scanner, (2) quantify the effect of disc degeneration on the NP shear modulus measured using magnetic resonance elastography, and (3) compare the NP shear modulus to other magnetic resonance-based biomarkers of dis degeneration.
Methods: Thirty intact human disc segments were classified as normal, mild, or severely degenerated. The NP shear modulus was measured using a custom-made setup that included a novel inverse method less sensitive to noisy displacements. T2 relaxation time was measured at 7T. The accuracy of these parameters to classify different degrees of degeneration was evaluated using receiver operating characteristic curves.
Results: The magnetic resonance elastography measure of shear modulus in the NP was able to differentiate between normal, mild degeneration, and severe degeneration. The T2 relaxation time was able to differentiate between normal and mild degeneration, but it could not distinguish between mild and severe degeneration.
Conclusions: This study shows that the NP shear modulus measured using magnetic resonance elastography is sensitive to disc degeneration and has the potential of being used as a clinical tool to quantify the mechanical integrity of the intervertebral disc.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3868648 | PMC |
http://dx.doi.org/10.1002/mrm.24895 | DOI Listing |
NPJ Comput Mater
January 2025
School of Mechanical, Aerospace, and Manufacturing Engineering, University of Connecticut, Storrs, CT USA.
Machine learning has advanced the rapid prediction of inorganic materials properties, yet data scarcity for specific properties and capturing thermodynamic stability remains challenging. We propose a framework utilizing a Graph Neural Network with composition-based and crystal structure-based architectures, combined with a transfer learning scheme. This approach accurately predicts energy-related properties (e.
View Article and Find Full Text PDFACS Earth Space Chem
January 2025
Department of Physics and Astronomy, University of Texas at San Antonio, San Antonio, Texas 78249, United States.
In this study, we measured the single-crystal elasticity of α-hydroquinone at ambient conditions using Brillouin spectroscopy to assess the feasibility of this technique for studying the mechanical properties of organic ices in the outer solar system. In this study, α-hydroquinone serves as an ambient temperature analogue for low-temperature organic ices on Titan and other solar system bodies. We found that a satisfactory Brillouin spectrum can be obtained in less than 5 min of experimental time with negligible damage to the sample.
View Article and Find Full Text PDFUltrasonics
January 2025
Acoustic and Application Group, Federal University of Alagoas, Campus Arapiraca, Brazil. Electronic address:
3D printing technology, also known as Additive Manufacturing (AM), has revolutionized object prototyping, offering a simple, cost-effective, and efficient approach to creating structures with diverse spatial features. However, the mechanical properties of 3D-printed structures are highly dependent on the material type and manufacturing technique employed. In this study, ultrasonic testing methods were used to comprehensively characterize standard samples produced using two popular printing techniques: material extrusion and vat photopolymerization.
View Article and Find Full Text PDFHeliyon
January 2025
Faculty of Engineering and Natural Sciences, Istanbul Okan University, Istanbul, Turkey.
This study considers Timoshenko beam theory and the isogeometric analysis method to investigate the free vibration and buckling of axially functionally graded (AFG) tapered beams. The governing equations are obtained from the kinematic assumptions of Timoshenko beam theory and Hamilton's principle. The isogeometric analysis approach is implemented to solve the motion equations.
View Article and Find Full Text PDFVasc Med
January 2025
Department of Surgery, Section of Vascular Surgery, Conrad Jobst Vascular Laboratories, University of Michigan Health System, Ann Arbor, MI, USA.
Interventional therapies to relieve chronic deep vein thrombosis (DVT) fail through inability to penetrate, cross, and remove the occlusion. Development of suitable tools requires fundamental understanding of chronic DVT mechanical properties and a reliable model for testing. Female farm swine underwent a novel, endovenous generation of long-segment unilateral iliac vein thrombosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!