Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The purpose of our study is to report our experience with the use of an ethylene vinyl alcohol copolymer (Onyx) in an off-label fashion for the treatment of type II endoleak after endovascular repair of the thoracic (TEVAR) and abdominal (EVAR) aorta.
Methods: A retrospective review of patients with type I and/or II endoleak treated with Onyx was performed. Data regarding the technical, clinical, and imaging outcomes were collected. Technical success was defined as decreased or eliminated endoleak on the first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up.
Results: Eighteen patients (15 male, 3 female) with a mean age of 79 years (range 69-92) met inclusion criteria (16 abdominal aortic aneurysm, 2 thoracic aortic aneurysm). Sixteen patients had type II endoleak, and 2 had complex type II endoleak with a type I component. The interval between endograft placement and treatment was a mean of 30 months. Direct sac treatment approach was used in 13 patients; transarterial approach was used in 3 patients. Seven patients required the use of coils, N-butyl cyanoacrylate glue, or Amplatzer vascular plugs. The average volume of Onyx used per treatment was 5.6 mL (range 2.5-13). Duration of imaging follow-up was 0.75-72.5 months (mean 32.8). Sixteen of 18 (88.9 %) patients had initial technical and clinical success. Two of 18 patients (11.1 %) were initial technical failures, and 1 remained a failure despite a second treatment and attempted surgical ligation. Eight of 18 (44.4 %) of patients eventually required a second intervention, 5 (27.8 %) of them due to delayed clinical failure. Complications included 1 psoas hematoma, 1 transient L2 nerve paresis, and 1 intraperitoneal Onyx leak; all of these were without clinical sequelae.
Conclusion: Onyx with or without coil/glue/Amplatzer plug embolization is safe and useful in the treatment of type II endoleak after TEVAR and EVAR. However, long-term clinical and imaging follow-up is needed for early detection and management of recurrence of the primary endoleak or the development of new, secondary endoleaks or enlargement of the aneurysm sac.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00270-013-0706-z | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!