A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Extending high-finesse cavity techniques to the far-infrared. | LitMetric

Sensitive spectroscopic techniques involving high-finesse Fabry-Perot resonators are widely used in the microwave and near-infrared spectral regimes, but hardware limitations have hindered their extension to far-infrared wavelengths. While there is no theoretical limit to the frequency region where cavity-enhanced techniques are practical, the sensitivity of these methods does depend explicitly on the availability of highly reflective optics and, in the case of cavity ringdown spectroscopy, sufficiently fast detectors. Here, we describe a novel high-finesse cavity that uses wire-grid polarizers as the reflective surfaces. Quality factors on the order of 10(5) are achieved at 250 GHz. Based on the optimized cavity design, we investigate the feasibility of extending the cavity ringdown technique to far-infrared wavelengths. With the present commercially available technology, we find spectrometer performance to be limited by both the available optics and detectors. With a 120 cm cavity and a detector response time of ~500 ns, we predict a minimum detectable absorption coefficient, αmin, on the order of 10(-7) cm(-1). Given the sensitivity and noise requirements for the ringdown measurements, faster and more sensitive detectors are needed before implementation of the spectrometer is practical or offers any significant advances to existing methods at far-infrared wavelengths.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4813274DOI Listing

Publication Analysis

Top Keywords

far-infrared wavelengths
12
high-finesse cavity
8
cavity ringdown
8
cavity
6
extending high-finesse
4
cavity techniques
4
far-infrared
4
techniques far-infrared
4
far-infrared sensitive
4
sensitive spectroscopic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!