Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Middle ear muscle reflex (MEMR) measurements have been a part of the standard clinical immittance test battery for decades as a cross-check with the behavioral audiogram and as a way to separate cochlear from retrocochlear pathologies. MEMR responses are measured in the ear canal by using a probe stimulus (e.g., single frequency or broadband noise) to monitor admittance changes elicited by a reflex-activating stimulus. In the clinical MEMR procedures, one test yields changes in a single measurement (i.e., admittance) at a single pure tone (e.g., 226 or 1000 Hz). In contrast, for the wideband acoustic immittance (WAI) procedure,one test yields information about multiple measurements (e.g., admittance, power reflectance, absorbance) across a wide frequency range (e.g., 250 to 8000 Hz analysis bandwidth of the probe). One benefit of the WAI method is that the MEMR can be identified in a single test regardless of the frequency at which the maximum shift in the immittance measurement occurs; this is beneficial because maximal shifts in immittance vary as a function of age and other factors. Another benefit is that the wideband response analysis yields lower MEMR thresholds than with the clinical procedures. Lower MEMR thresholds would allow for MEMR decay tests in ears in which the activator levels could not be safely presented. Finally, the WAI procedures can be automated with objective identification of the MEMR, which would allow for use in newborn and other screening programs in which the tests are completed by nonaudiological personnel.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/AUD.0b013e31829c70d9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!