A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of a micellar liquid chromatographic method for determination of caffeine and non-steroidal anti-inflammatories. | LitMetric

Validation of a micellar liquid chromatographic method for determination of caffeine and non-steroidal anti-inflammatories.

J Chromatogr Sci

Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt

Published: September 2014

An accurate, simple, sensitive and selective micellar liquid chromatographic method has been developed for the simultaneous determination of caffeine (CAF) and two non-steroidal anti-inflammatory drugs, namely ibuprofen (IBU) and ketoprofen (KET). The chemometric approach was applied to the optimization of separation of the studied drugs. To optimize their separation, the effect of six experimental parameters on retention was investigated by means of multivariate analysis. Separation was conducted using an ODS C18 (150 × 4.6 mm i.d.) stainless steel column at ambient temperature with UV detection at 260 nm. A mobile phase composed of 40 mM sodium dodecyl sulphate (SDS), 10% 1-propanol and 0.3% tri-ethylamine in 0.02 M phosphoric acid adjusted to pH 3 has been used at a flow rate of 1 mL/min. Regression models were characterized by both descriptive and predictive ability (R(2) ≥ 97.9% and R(cv)(2) ≥ 96.2%) and allowed the chromatographic separation of the drugs with a good resolution and a total analysis time within 15 min. The calibration curves were rectilinear over the concentration ranges of 2.0-25.0, 1.5-15.0 and 1.0-10.0 µg/mL for IBU, KET and CAF, respectively, with detection limits of 1.2, 1.0 and 0.6 µg/mL, and quantification limits of 1.6, 1.2 and 0.8 µg/mL, respectively. The results obtained were in good agreement with those obtained by the comparison method.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmt117DOI Listing

Publication Analysis

Top Keywords

micellar liquid
8
liquid chromatographic
8
chromatographic method
8
determination caffeine
8
limits µg/ml
8
validation micellar
4
method determination
4
caffeine non-steroidal
4
non-steroidal anti-inflammatories
4
anti-inflammatories accurate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!