Biological and electrophysiologic effects of poly(3,4-ethylenedioxythiophene) on regenerating peripheral nerve fibers.

Plast Reconstr Surg

Charleston, S.C.; Ann Arbor and Detroit, Mich.; Incheon, South Korea; and Newark, Del. From the Division of General Surgery, Department of Surgery, Medical University of South Carolina; the Section of Plastic and Reconstructive Surgery, Department of Surgery, and the Department of Biomedical Engineering, University of Michigan; the Division of General Surgery, Department of Surgery, Henry Ford Hospital-Wayne State University; the Department of Chemical and Biological Engineering, Inha University; and the Department of Materials Science and Engineering, University of Delaware.

Published: August 2013

Background: Uninjured peripheral nerves in upper-limb amputees represent attractive sites for connectivity with neuroprostheses because their predictable internal topography allows for precise sorting of motor and sensory signals. The inclusion of poly(3,4-ethylenedioxythiophene) reduces impedance and improves charge transfer at the biotic-abiotic interface. This study evaluates the in vivo performance of poly(3,4-ethylenedioxythiophene)-coated interpositional decellularized nerve grafts across a critical nerve conduction gap, and examines the long-term effects of two different poly(3,4-ethylenedioxythiophene) formulations on regenerating peripheral nerve fibers.

Methods: In 48 rats, a 15-mm gap in the common peroneal nerve was repaired using a nerve graft of equivalent length, including (1) decellularized nerve chemically polymerized with poly(3,4-ethylenedioxythiophene) (dry); (2) decellularized nerve electrochemically polymerized with poly(3,4-ethylenedioxythiophene) (wet); (3) intact nerve; (4) autogenous nerve graft; (5) decellularized nerve alone; and (6) unrepaired nerve gap controls. All groups underwent electrophysiologic characterization at 3 months, and nerves were harvested for histomorphometric analysis.

Results: Conduction velocity was significantly faster in the dry poly(3,4-ethylenedioxythiophene) group compared with the sham, decellularized nerve, and wet poly(3,4-ethylenedioxythiophene) groups. Maximum specific force for the dry poly(3,4-ethylenedioxythiophene) group was more similar to sham than were decellularized nerve controls. Evident neural regeneration was demonstrated in both dry and wet poly(3,4-ethylenedioxythiophene) groups by the presence of normal regenerating axons on histologic cross-section.

Conclusions: Both poly(3,4-ethylenedioxythiophene) formulations were compatible with peripheral nerve regeneration at 3 months. This study supports poly(3,4-ethylenedioxythiophene) as a promising adjunct for peripheral nerve interfaces for prosthetic control and other biomedical applications because of its recognized ionic-to-electronic coupling potential.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206183PMC
http://dx.doi.org/10.1097/PRS.0b013e3182959f63DOI Listing

Publication Analysis

Top Keywords

decellularized nerve
24
nerve
16
peripheral nerve
16
poly34-ethylenedioxythiophene
11
effects poly34-ethylenedioxythiophene
8
regenerating peripheral
8
poly34-ethylenedioxythiophene formulations
8
nerve graft
8
polymerized poly34-ethylenedioxythiophene
8
dry poly34-ethylenedioxythiophene
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!