Background/aim: It has been proposed that the narrow diameter of the appendix is important in providing a 'safe zone' for commensal intestinal flora, while the length of the appendix can be variable. This study aimed to investigate the relationship between appendiceal length, diameter and age, in children under the age of eighteen years, to determine if the appendix changes in size with age.
Methods: The histological records of all cases of children undergoing appendicectomy at the Royal Children's Hospital (Melbourne) between 2009 and 2011 were retrospectively reviewed. Participants were excluded on the basis of histological evidence of acute inflammation, and data on the diameter and length of the appendix were collected from 210 children, aged zero to seventeen years.
Results: Data were stratified by age for analysis into ≤ 3 years, >3 and ≤ 9, >9 and ≤ 13 and >13 years. Mean diameters per group were 3.7 (± 1.3), 6.3 (± 1.2), 6.7 (± 1.6) and 6.9 (± 1.6) millimetres respectively. Mean lengths per group were 39.7 (± 16.1), 66.3 (± 15.3), 63.7 (± 21.3) and 68.8 (± 18.2) millimetres. Both diameter and length were higher in the older age groups, compared with the ≤ 3 year olds (p < 0.001). A positive correlation was seen between age and appendix diameter (R = 0.5, p < 0.001) and length (R = 0.3, p=0.03) in the ≤ 3 group only. Mean diameter and length values did not differ significantly between groups aged > 3 years old.
Conclusion: This study showed that following an initial growth period during early infancy up to about 3 years, the appendix achieves its adult proportions and does not continue to grow throughout childhood.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpedsurg.2013.02.035 | DOI Listing |
Front Vet Sci
December 2024
Department of Veterinary Clinical Science, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Republic of Korea.
Introduction: The objective of this study is to analyze the morphology and measurement dimensions of patent ductus arteriosus (PDA) based on computed tomography images.
Methods: The present study retrospectively evaluated computed tomography angiography data from 25 client-owned dogs diagnosed with PDA. PDA was reconstructed based on the central axis and the minimum diameter, ampulla diameter, angle, ampulla cross-section area, and length values were measured at specific measurement sites.
Small
January 2025
Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education of the People's Republic of China, Heilongjiang University, Xuefu Road, Harbin, 150080, P. R. China.
The bi-transition-metal interstitial compounds (BTMICs) are promising for water electrolysis. The previous BTMICs are usually composed of irregular particles. Here, this work shows the synthesis of novel 1D CoMoC-based heterojunction nanowires (1D Co/CoMoC) with diameters about 50 nm and a length-to-diameter ratio about 20 for efficient water electrolysis.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Thoracic Surgery, The First People's Hospital of Jiande, Jiande, China.
Background: The correlation between central airway anatomical parameters and demographic factors, such as sex, age, weight, height, body mass index (BMI), and cardiac factors, remains unclear. This study examined the correlation between these factors and central airway anatomical parameters in adult patients.
Methods: All consecutive patients who underwent lung mass surgery at our hospital between December 2020 and December 2023 were included in this study.
Arch Virol
January 2025
Jiangsu Province Engineering Research Center for Marine Bio-resources Sustainable Utilization, College of Oceanography, Hohai University, Nanjing, Jiangsu, China.
In this study, a lytic phage, named PG216, was obtained from seawater collected in Qingdao, using Vibrio parahaemolyticus strain G299 as its host. Transmission electron microscopy revealed that phage PG216 has an icosahedral head with a diameter of 100 ± 6.7 nm and a contractible tail with a length of 126 ± 6.
View Article and Find Full Text PDFRadiat Prot Dosimetry
January 2025
Medical Physics, Ghent University, Proeftuinstraat 86, 9000 Ghent, Belgium.
Quality control (QC) of personal radiation protective equipment (PRPE) is essential to detect tears and holes in the attenuating layers. Routinely, this QC is performed using fluoroscopy on a conventional X-ray table. However, such a QC procedure is laborious and time consuming.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!