A new method of generating realistic three dimensional simulated breast lesions known as diffusion limited aggregation (DLA) is presented, and compared with the random walk (RW) method. Both methods of lesion simulation utilize a physics-based method for inserting these simulated lesions into 2D clinical mammogram images that takes into account the polychromatic x-ray spectrum, local glandularity and scatter. DLA and RW masses were assessed for realism via a receiver operating characteristic (ROC) study with nine observers. The study comprised 150 images of which 50 were real pathology proven mammograms, 50 were normal mammograms with RW inserted masses and 50 were normal mammograms with DLA inserted masses. The average area under the ROC curve for the DLA method was 0.55 (95% confidence interval 0.51-0.59) compared to 0.60 (95% confidence interval 0.56-0.63) for the RW method. The observer study results suggest that the DLA method produced more realistic masses with more variability in shape compared to the RW method. DLA generated lesions can overcome the lack of complexity in structure and shape in many current methods of mass simulation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/58/16/5613 | DOI Listing |
Eur J Nucl Med Mol Imaging
January 2025
Department of Nuclear Medicine and Minnan PET Center, Xiamen Key Laboratory of Radiopharmaceuticals, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China.
Purpose: To evaluate the diagnostic accuracy and clinical impact of fibroblast activation protein (FAP)-targeted PET/CT imaging in primary and metastatic breast cancer and compare the results with those of standard-of-care imaging (SCI) and [F]FDG PET/CT.
Methods: We prospectively analyzed patients with diagnosed or suspected breast cancer who underwent concomitant FAP-targeted PET/CT (radiotracers including either [Ga]Ga-FAPI-46 or [F]FAPI-42) and [F]FDG PET/CT scans from June 2020 to January 2024 at two medical centers. Breast ultrasound (US) imaging was performed in all treatment-naïve patients as SCI.
Arch Gynecol Obstet
January 2025
Department of Obstetrics and Gynecology, Breast Cancer Center, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120, Heidelberg, Germany.
Purpose: Artificial Intelligence models based on medical (imaging) data are increasingly developed. However, the imaging software on which the original data is generated is frequently updated. The impact of updated imaging software on the performance of AI models is unclear.
View Article and Find Full Text PDFCureus
December 2024
Surgery, All India Institute of Medical Sciences, New Delhi, IND.
Recurrence beyond the second year of diagnosis and metastasis to the skin and eyelids are rare occurrences in breast cancer. When cutaneous metastases present without local recurrence, they pose a significant diagnostic challenge. Here, we describe a case of breast cancer that recurred 16 years after the initial treatment, with the only indication of recurrence being unusual skin and eyelid lesions.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Physics and Astronomy, University of California - Irvine, Irvine, California, USA.
Background: K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons.
View Article and Find Full Text PDFAnn Surg Oncol
January 2025
Department of Breast Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Background: Atypical ductal hyperplasia (ADH) is a benign proliferative breast lesion. Surgical excision of ADH is often recommended to rule out underlying malignant disease.
Objective: The aim of this study was to evaluate the trends in ADH upgrade rates over time and identify the impact of magnetic resonance imaging (MRI) use on upgrade rates.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!