Laboratories focusing on residue analysis in food are continuously seeking to increase sample throughput by minimizing sample preparation. Generic sample extraction methods such as QuEChERS lack selectivity and consequently extracts are not free from non-volatile material that contaminates the analytical system. Co-extracted matrix constituents interfere with target analytes, even if highly sensitive and selective GC-MS/MS is used. A number of GC approaches are described that can be used to increase laboratory productivity. These techniques include automated inlet liner exchange and column backflushing for preservation of the performance of the analytical system and heart-cutting two-dimensional GC for increasing sensitivity and selectivity. The application of these tools is illustrated by the analysis of pesticides in vegetables and fruits, PCBs in milk powder and coplanar PCBs in fish. It is demonstrated that considerable increase in productivity can be achieved by decreasing instrument down-time, while analytical performance is equal or better compared to conventional trace contaminant analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2013.07.038 | DOI Listing |
J Long Term Eff Med Implants
December 2024
St. Joseph's Hospital, Paterson, New Jersey, USA.
Prosthetic bone and joint infections are difficult to treat with varying levels of success with standard therapy. Synthetic calcium sulfate carrier, to which specific antibiotics can be added, can be utilized as an alternative drug delivery system in these cases. We have reviewed clinical outcomes using commercially available pure synthetic calcium sulfate dissolvable beads (Stimulan) loaded with antibiotics in 143 patients undergoing orthopedic surgery for prevention and treatment of joint infection.
View Article and Find Full Text PDFArch Orthop Trauma Surg
December 2024
Bone and Joint Sports Medicine Institute, Department of Orthopaedic Surgery, Naval Medical Center Portsmouth, Portsmouth, VA, USA.
Introduction: The increased use of the direct anterior approach (DAA) for primary total hip arthroplasty (THA) has extended to revision THA. This systematic review evaluated studies reporting both the utility and clinical outcomes of revision THA using DAA, focusing on studies comparing revision approaches.
Materials And Methods: A review of the Cochrane Library, EMBASE, and MEDLINE databases identified 577 publications.
J Orthop Case Rep
December 2024
Department of Orthopaedics, AIIMS Raebareli, Raebareli, Uttar Pradesh, India.
Introduction: Metallosis, characterized by the collection of metallic debris in periarticular tissues, is primarily associated with metal-on-metal bearings in hip arthroplasty. This report presents a rare case of metallosis after metal-on-polyethylene (MoP) total hip arthroplasty (THA), highlighting diagnostic challenges and management strategies. Metallosis following MoP arthroplasty is extremely rare, with only a limited number of documented cases in the literature.
View Article and Find Full Text PDFHSS J
March 2024
Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Introduction: Instability after total knee arthroplasty (TKA) remains a leading cause of revision TKA and can lead to patient dissatisfaction. While many companies have developed midlevel constrained (MLC) polyethylene inserts in primary TKAs, there is little data on their outcomes.
Purpose: We sought to analyze short-term outcomes including survivorship, rates of manipulation under anesthesia (MUA), and improvements in patient-reported outcome measures (PROMs) preoperatively to postoperatively in one design of MLC TKA.
JBJS Essent Surg Tech
November 2024
University of Zürich, Zürich, Switzerland.
Background: Although the direct anterior approach (DAA) represents an intermuscular and internervous approach to total hip arthroplasty (THA), it did not reach global acceptance until its adoption by large teaching centers. Today, >50% of primary THA procedures in Switzerland are performed via the DAA. Besides being truly minimally invasive, a key advantage of the DAA is the inherent stability that it provides.