A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The evaluation of 25 chiral stationary phases and the utilization of sub-2.0μm coated polysaccharide chiral stationary phases via supercritical fluid chromatography. | LitMetric

A rapid screening method to identify the best conditions for chiral separations is described. We analyzed a representative set of 80 racemic compounds against 25 different chiral stationary phases with three different mobile phases to identify the combination of columns and mobile phases that will separate the most compounds on the initial screen. While the OD separated the largest number of compounds, we found the best combination of six columns to be the AD, AS, AY, CC4, ID and Whelk-O1. The second team included the CCC, Cellulose-1, Cellulose-3 or OJ, IA, IE and IF. All 80 compounds were separated with a resolution range of 0.65-15.36. Screening the covalently bonded phases provided separation for 79 of the 80 compounds. We also found ethanol (0.1% NH4OH) separated more compounds than methanol (0.1% NH4OH) or isopropanol (0.1% NH4OH). As part of this study, we also compared the effectiveness of stationary phases that have the same chiral selector. Finally, we demonstrated the effectiveness of using a fast, 1.5-min screening method that utilizes a 1.7μm coated polysaccharide chiral stationary phase.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2013.07.046DOI Listing

Publication Analysis

Top Keywords

chiral stationary
16
stationary phases
16
01% nh4oh
12
coated polysaccharide
8
polysaccharide chiral
8
screening method
8
mobile phases
8
combination columns
8
phases
7
compounds
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!