A rapid screening method to identify the best conditions for chiral separations is described. We analyzed a representative set of 80 racemic compounds against 25 different chiral stationary phases with three different mobile phases to identify the combination of columns and mobile phases that will separate the most compounds on the initial screen. While the OD separated the largest number of compounds, we found the best combination of six columns to be the AD, AS, AY, CC4, ID and Whelk-O1. The second team included the CCC, Cellulose-1, Cellulose-3 or OJ, IA, IE and IF. All 80 compounds were separated with a resolution range of 0.65-15.36. Screening the covalently bonded phases provided separation for 79 of the 80 compounds. We also found ethanol (0.1% NH4OH) separated more compounds than methanol (0.1% NH4OH) or isopropanol (0.1% NH4OH). As part of this study, we also compared the effectiveness of stationary phases that have the same chiral selector. Finally, we demonstrated the effectiveness of using a fast, 1.5-min screening method that utilizes a 1.7μm coated polysaccharide chiral stationary phase.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2013.07.046DOI Listing

Publication Analysis

Top Keywords

chiral stationary
16
stationary phases
16
01% nh4oh
12
coated polysaccharide
8
polysaccharide chiral
8
screening method
8
mobile phases
8
combination columns
8
phases
7
compounds
6

Similar Publications

Enantioseparation and enantiorecognition are crucial in the pharmaceutical analysis of chiral substances, impacting safety, efficacy, and regulatory compliance. Enantioseparation refers to the process of separating enantiomers from a mixture, typically achieved through chromatography techniques like HPLC and SFC. In contrast, enantiorecognition involves the identification of enantiomers based on their interaction with a chiral selector without the need for separation.

View Article and Find Full Text PDF

This work explores the use of a cross-shaped organic framework that is used as a template for the investigation of multi-functionalized chromophores. We report the design and synthesis of a universal cross-shaped building block bearing two bromines and two iodines on its peripheral positions. The template can be synthesized on a gram scale in a five-step reaction comprising an oxidative homo-coupling macro-cyclization.

View Article and Find Full Text PDF

Chiral macrocycles have emerged as attractive media for chromatographic enantioseparation due to their excellent host-guest recognition properties. In this study, a new chiral stationary phase (CSP) based on 1,1'-binaphthyl chiral polyimine macrocycle (CPM) was reported. The CPM was synthesized by one-step aldehyde-amine condensation of (S)-2,2'-dihydroxy-[1,1'-binaphthalene]-3,3'-dicarboxaldehyde with 1,2-phenylenediamine and bonded on thiolated silica via the thiol-ene click reaction to afford the CSP.

View Article and Find Full Text PDF

Simultaneous separation of the enantiomers of six anticoagulant rodenticides using chiral supercritical fluid chromatography-mass spectrometry.

J Chromatogr A

December 2024

I. U. CINQUIMA, Analytical Chemistry Group (TESEA), Dept. Analytical Chemistry, Faculty of Sciences, University of Valladolid 47011, Valladolid, Spain. Electronic address:

The simultaneous separation of the enantiomers of six anticoagulant rodenticides, derived from 4-hydroxycoumarin, has been studied in this work. Ten different stationary phases (zwitterionic, Pirkle-type, polysaccharides and macrocyclic antibiotics derivatives) were evaluated by using supercritical fluid chromatography coupled to two different detectors (circular dichroism and mass spectrometry-single quadrupole). The effect of the type of organic modifier and temperature on the chiral separation was investigated, and the best results were obtained with the column Regis S,S-Whelk-O1 at 25 °C when using a gradient elution program with methanol as organic modifier.

View Article and Find Full Text PDF

Simultaneous separation and detection of common chiral and achiral metabolites in the urine of human exposed to benzene series by LC-MS/MS.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

School of Ecology and Environment, Yuzhang Normal University, No.1999, Meiling Ave., Honggutan Dist., Nanchang 330103, Jiangxi, China.

Benzene, toluene, and xylene (BTX) are priority pollutants known for their hematotoxicity and carcinogenic properties. Benzene is further metabolized to phenyl mercapturic acid (PMA), toluene and xylene also generate benzyl mercapturic acid (BMA) in human urine. To confirm whether the exposure to benzene series comes from the workplace or from the external environment such as smoking is a very meaningful work, so accurate measurement of their biomarkers in biological samples is crucial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!