Purpose: To determine whether volar locking plates are superior to external fixation with adjuvant pins in the treatment of unstable distal radius fractures.

Methods: A total of 111 unstable distal radius fractures were randomized to treatment with external fixation (EF) using adjuvant pins or with a volar locking plate (VLP). The mean age of the patients was 54 years (range, 20-84 y). Seven patients were lost to follow-up. At 1 year, 104 patients were assessed with a visual analog scale pain score, Mayo wrist score, Quick-Disabilities of the Arm, Shoulder, and Hand (QuickDASH), range of motion, and radiological evaluation. The QuickDASH score at 52 weeks was the primary outcome measure.

Results: The operative time in the EF group was 77 minutes, compared with 88 minutes in the VLP group. At 52 weeks, patients with VLPs had a higher Mayo wrist score (90 vs. 85), better supination (89° vs. 85°), and less radial shortening (+1.4 mm vs. +2.2 mm). There were more patients with pain over the ulnar styloid in the EF group (16 vs 6 patients). For AO type C2/C3, the patients with VLPs had better supination (90° vs. 76°) and less ulnar shortening (+1.1 mm vs. +2.8 mm). The complication rate was 30% in the EF group, compared with 29% in the VLP group. Eight (15%) plates were removed due to complications. The QuickDASH score was not significantly different between the groups.

Conclusions: Although we did not find a significant difference between the groups for the QuickDASH score, we believe that our results support the use of VLPs for the treatment of unstable distal radius fractures. A serious concern is that some patients will have to have their plates removed; therefore, improving the surgical technique is important.

Type Of Study/level Of Evidence: Therapeutic I.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2013.04.039DOI Listing

Publication Analysis

Top Keywords

unstable distal
16
distal radius
16
volar locking
12
external fixation
12
fixation adjuvant
12
radius fractures
12
quickdash score
12
locking plates
8
fractures randomized
8
adjuvant pins
8

Similar Publications

Background: This video article describes the use of bone-anchored prostheses for patients with transtibial amputations, most often resulting from trauma, infection, or dysvascular disease. Large studies have shown that about half of all patients with a socket-suspended artificial limb experience limited mobility and limited prosthesis use because of socket-related problems. These problems occur at the socket-residual limb interface as a result of a painful and unstable connection, leading to an asymmetrical gait and subsequent pelvic and back pain.

View Article and Find Full Text PDF

Background: Syndesmotic instability is a significant concern in the management of unstable ankle fractures, occurring in approximately 10% to 13% of these cases. Early recognition and stabilization of syndesmotic injuries are essential to ensure optimal long-term outcomes. Several techniques are currently in use, often involving complex procedure and/or costly devices.

View Article and Find Full Text PDF

Objective: To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).

Methods: Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.

View Article and Find Full Text PDF

Objective: To compare the effectiveness of clavicular hook plates and Endobutton plates in treating unstable distal clavicle fractures (UDCFs).

Methods: Data from 95 patients with UDCFs (Neer II and V types) were retrospectively analyzed. Among them, 55 cases were treated with clavicular hook plates (control group), and 40 cases with Endobutton plates (research group).

View Article and Find Full Text PDF

Extracorporeal Membrane Oxygenation Without Mechanical Ventilation for Recovery From Tracheal Repair.

Ann Thorac Surg Short Rep

June 2024

Division of Cardiothoracic Surgery, Department of Surgery, University of Kentucky, Lexington, Kentucky.

Postoperative positive pressure ventilation (PPV) can contribute to failure of large intrathoracic airway repairs. We report a case of a 67-year-old woman with severe emphysema who presented with an unstable airway and mediastinitis after full-length transmural intrathoracic tracheal intubation injury. After repair, neither extubation nor PPV distal to the repair was feasible.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!