Effects of biventricular pacing on left heart twist and strain in a porcine model of right heart failure.

J Surg Res

Department of Surgery, Columbia Presbyterian Medical Center, New York, New York; Department of Surgery, Duke University Medical Center, Durham, North Carolina.

Published: December 2013

Background: Biventricular pacing (BiVP) improves cardiac output (CO) in selected cardiac surgery patients, but response remains variable, necessitating a better understanding of the mechanism. Accordingly, we used speckle tracking echocardiography (STE) to analyze BiVP during acute right ventricular pressure overload (RVPO).

Materials And Methods: In nine pigs, the inferior vena cava (IVC) was snared to decrease CO and establish a control model. Heart block was induced, the pulmonary artery snared, and BiVP initiated. Echocardiograms of the left ventricular midpapillary level were taken at varying atrioventricular delay (AVD) and interventricular delay (VVD) for STE analysis of regional circumferential strain (CS) and radial strain (RS). Echocardiograms were taken of the left ventricular base, midpapillary, and apex during baseline, IVC occlusion, and each BiVP setting for STE analysis of twist, apical and basal rotations, CS, RS, and synchrony. Indices were correlated against CO with mixed linear models.

Results: During IVC occlusion, CO correlated with twist, apical rotation, RS, RS synchrony, and CS (P < 0.05). During RVPO with BiVP, CO only correlated with RS synchrony and CS (P < 0.05). During AVD and VVD variations, CO was associated with free wall RS (P < 0.008). CO correlated with septal wall CS during AVD variation and free wall CS during VVD variation (P < 0.008).

Conclusions: In an open chest model, twist, RS, RS synchrony, and CS analyzed by STE may be noninvasive surrogates for changes in CO. During RVPO, changes in RS synchrony and CS with varying regional strain contributions may be the primary mechanism in which BiVP improves CO. Lack of correlation of remaining indices may reflect postsystolic function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5717762PMC
http://dx.doi.org/10.1016/j.jss.2013.06.038DOI Listing

Publication Analysis

Top Keywords

biventricular pacing
8
model heart
8
echocardiograms left
8
left ventricular
8
ste analysis
8
ivc occlusion
8
twist apical
8
bivp
5
effects biventricular
4
pacing left
4

Similar Publications

Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.

View Article and Find Full Text PDF

This paper reviews the literature on assessing electrical dyssynchrony for patient selection in cardiac resynchronization therapy (CRT). The guideline-recommended electrocardiographic (ECG) criteria for CRT are QRS duration and morphology, established through inclusion criteria in large CRT trials. However, both QRS duration and LBBB morphology have their shortcomings.

View Article and Find Full Text PDF

: Heart failure is the leading cause of hospital admission and mortality. Racial disparities have been demonstrated in various cardiovascular disorders; however, the data for in-hospital outcomes, complications, and procedural rates are limited. : Utilizing the National Inpatient Sample (NIS) database, this retrospective cohort study included adult patients admitted with a principal diagnosis of heart failure.

View Article and Find Full Text PDF

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

An infant with DiGeorge syndrome, multiple comorbidities, and truncus arteriosus type II underwent repair complicated by heart block necessitating placement of a dual-chamber bipolar pacing system with right ventricular leads and subsequent resynchronization with placement of left ventricular apical pacing leads. Resynchronization therapy improved QRS duration from 180 ms to 100 ms and ejection fraction from 25% to 54% over the course of 4 weeks with gradual return to normal function and eventual discharge.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!