Purpose: This study aimed to quantify the costs of complete denture fabrication by a simplified method compared with a conventional protocol.
Materials And Methods: A sample of edentulous patients needing conventional maxillary and mandibular complete dentures was randomly divided into group S, which received dentures fabricated by a simplified method, and group C, which received conventionally fabricated dentures. We calculated direct and indirect costs for each participant including unscheduled procedures. This study assessed 19 and 20 participants allocated into groups S and C, respectively, and comparisons between groups were conducted by the Mann-Whitney and Student's t-test (α = 0.05).
Results: Complete denture fabrication demanded median time periods of 173.2 and 284.5 minutes from the operator for groups S and C respectively, and 46.6 and 61.7 minutes from the dental assistant (significant differences, p < 0.05). There was no difference between groups regarding postinsertion adjustments. Group S showed lower values for costs with materials and time spent by patients than group C during the fabrication stage, but not during adjustments.
Conclusions: The median direct cost of complete denture treatment was 34.9% lower for the simplified method. It can be concluded that the simplified method is less costly for patients and the health system when compared with a conventional protocol for the rehabilitation of edentulous patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jopr.12090 | DOI Listing |
Int J Implant Dent
January 2025
Lecturer at removable prosthodontic department, Faculty of dental medicine for Girls, Al-Azhar University, Cairo, Egypt.
BMC Oral Health
January 2025
Faculty of Dentistry, British University in Egypt (BUE), Shorouk, Egypt.
Purpose: This study aimed to compare different treatment modalities to correct ill-fitted maxillary complete denture either by the conventional relining method or by scanning the relining impression and digitally construct a new denture regarding patient satisfaction, denture retention, and adaptation.
Materials And Methods: Twelve edentulous patients suffering from loose maxillary complete dentures were selected, dentures' borders and fitting surfaces were prepared, and relining impressions were taken, the impressions were scanned and the STL files were used for CAD/CAM milling ( computer aided designing/ computer aided manufacturing) of new maxillary dentures (Group A), then the relining impression went through the conventional laboratory steps to fabricate (Group B) maxillary dentures. Both groups were evaluated regarding patient satisfaction by a specially designed questionnaire, retention values were measured by a digital force gauge at denture insertion appointment and two weeks later, geomagic software was used to evaluate dentures adaptation to oral tissues.
J Prosthodont
January 2025
Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.
Purpose: This study aims to evaluate the effectiveness of a case-based reasoning (CBR) system in predicting the design of definitive obturator prostheses for maxillectomy patients.
Materials And Methods: Data from 209 maxillectomy cases, including extraoral images of obturator prostheses and occlusal images of maxillectomy defects, were collected from Institute of Science Tokyo Hospital. These cases were organized into a structured database using Python's pandas library.
J Prosthet Dent
January 2025
Assistant Professor, Department of Prosthodontic, College of Dental Medicine, Rangsit University, Phatum Thani, Thailand. Electronic address:
Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.
Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.