Background: Delayed postnatal removal of lung liquid may result in respiratory distress, which is more common in infants born by cesarean section. Vertical artefacts (B-lines) arising from the lung surface in lung ultrasound have been shown to correlate with the liquid content of the lungs.

Objectives: We studied whether lung ultrasound could be used for the assessment of postnatal lung liquid in healthy term infants born vaginally and by cesarean section.

Methods: Lung ultrasound was performed 1, 3 and 24 h after birth to 22 vaginally born infants and 20 infants born by elective cesarean section. The abundance of B-lines was scored for each infant and time point by two independent observers blinded to the mode of delivery and time point on the examination on a five-step scale.

Results: In both groups, a significant decrease in abundance of B-lines, indicative of lung liquid absorption, was observed during the first 24 h. 3 h after birth cesarean section was associated with significantly higher lung liquid content than vaginal delivery.

Conclusion: The noninvasive bedside ultrasound method for estimation of lung liquid is a promising tool for the early identification of infants at risk for pulmonary maladaptation.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000351290DOI Listing

Publication Analysis

Top Keywords

lung liquid
24
infants born
12
lung ultrasound
12
lung
9
liquid absorption
8
liquid content
8
abundance b-lines
8
time point
8
liquid
7
cesarean
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!