In unilateral upper-limb complex regional pain syndrome (CRPS), the temperature of the hands is modulated by where the arms are located relative to the body midline. We hypothesized that this effect depends on the perceived location of the hands, not on their actual location, nor on their anatomical alignment. In 2 separate cross-sectional randomized experiments, 10 (6 female) unilateral CRPS patients wore prism glasses that laterally shifted the visual field by 20°. Skin temperature was measured before and after 9-minute periods in which the position of one hand was changed. Placing the affected hand on the healthy side of the body midline increased its temperature (Δ°C=+0.47 ± 0.14°C), but not if prism glasses made the hand appear to be on the body midline (Δ°C=+0.07 ± 0.06°C). Similarly, when prism glasses made the affected hand appear to be on the healthy side of the body midline, even though it was not, the affected hand warmed up (Δ°C=+0.28 ± 0.14°C). When prism glasses made the healthy hand appear to be on the affected side of the body midline, even though it was not, the healthy hand cooled down (Δ°C=-0.30 ± 0.15°C). Friedman's analysis of variance and Wilcoxon pairs tests upheld the results (P<0.01 for all). We conclude that, in CRPS, cortical mechanisms responsible for encoding the perceived location of the limbs in space modulate the temperature of the hands.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.pain.2013.07.026 | DOI Listing |
Sci Rep
January 2025
Physics Department, Faculty of Sciences, TH-PPM Group, Beni-Suef University, Beni Suef, 62514, Egypt.
This theoretical work focuses on the application of Tamm resonance-based biosensing using a one-dimensional photonic crystal for detecting skin vitiligo, a condition caused by the loss of pigment in the body. This biosensor utilizes the interaction of light with the photonic structure to identify the specific biomarkers associated with vitiligo. The proposed structure is composed of prism/Ag/skin-sample/(GaP/PS)/glass.
View Article and Find Full Text PDFBMC Ophthalmol
December 2024
Department of Ophthalmology, Children's Hospital of Nanjing Medical University, 72 Guangzhou Road, Gulou District, Nanjing, 210008, Jiangsu Province, China.
Objective: This study aimed to conduct a network meta-analysis to evaluate the efficacy of various non-surgical treatments for intermittent exotropia(IXT).
Methods: A comprehensive search of the PubMed, EMbase, and Cochrane Library databases was performed to identify relevant randomized controlled trials (RCTs) up to June 2024. Following independent screening, data extraction, and bias assessment by two researchers, network meta-analysis was conducted using R 4.
Klin Monbl Augenheilkd
December 2024
Glaucoma drainage devices (GDD) are used for patients with secondary glaucoma, such as uveitic or neovascular glaucoma, which is uncontrolled under local therapy. They are also used in patients with conjunctival scarring, for example after a previous vitrectomy or after unsuccessful previous glaucoma surgery, such as trabeculectomy. They are also a treatment option for congenital glaucoma, aphakic glaucoma or for the treatment of iridocorneoendothelial syndromes.
View Article and Find Full Text PDFWorld Neurosurg
December 2024
Neurosurgery Department, Sainte-Anne Military Teaching Hospital, Toulon, France. Electronic address:
Cavernous malformations are low-flow fragile vascular lesions prone to extralesional bleeding that can occur in the cerebral hemispheres, the brainstem, or the spinal cord. This paper reports the case of a 32-year-old right-handed man with acute-onset headaches associated with right-sided tinnitus, right-sided hemianesthesia, and binocular diplopia related to cranial nerve IV palsy. Neuroimaging displayed left-sided isolated cavernous malformation of the inferior tectal plate, with evidence of extralesional bleeding.
View Article and Find Full Text PDFIndian J Ophthalmol
October 2024
Department of Ophthalmology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Purpose: In clinical ophthalmology, prisms, commonly made of glass, are labeled based on the prism diopter (PD) value measured in the anterior Prentice position. However, they are often used in the posterior parallel position for practicality, causing a discrepancy between labeled and effective PD. This study proposes a conversion tool to address this issue.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!