A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective multi-center dosimetry study of low-dose Iodine-125 prostate brachytherapy performed after transurethral resection. | LitMetric

Purpose: To evaluate in a multicenter setting the ability of centers to perform pre-implant permanent prostate brachytherapy planning, fulfilling dosimetric goals and constraints based on the Groupe de Curiethérapie-European Society for Radiotherapy and Oncology guidelines in the setting of implantation after prior prostate transurethral resection (TURP).

Material And Methods: A reference transrectal ultrasound image set of the prostate gland from a patient who had undergone TURP was used. Contouring of the prostate, clinical target volume and organs at risk was performed by the coordinating center. Goals and constraints regarding the dosimetry were defined.

Results: Seventeen of twenty-five centers invited to participate were able to import the Digital Imaging and Communications in Medicine-images into their planning computer and plan the implant using the defined guidelines. All centers were able to plan treatment, and achieve the recommended objectives and constraints. However, sector analysis has shown a risk of under-dosage in the anterior part of the prostate.

Conclusions: Correct pre-implantation planning with adherence to protocol guidelines and in compliance with defined dosimetric constraints seems feasible in a post-TURP setting, at least on a theoretical basis. A prospective study evaluating the outcome of prostate brachytherapy performed after TURP can therefore be undertaken with an expectation of a correct dosimetry in the multicenter setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3708148PMC
http://dx.doi.org/10.5114/jcb.2013.36174DOI Listing

Publication Analysis

Top Keywords

prostate brachytherapy
12
brachytherapy performed
8
transurethral resection
8
multicenter setting
8
goals constraints
8
prostate
6
prospective multi-center
4
multi-center dosimetry
4
dosimetry study
4
study low-dose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!