Objectives: The long-term performance of polymer-free stent systems in patients with diabetes mellitus has not been investigated extensively. This study reports long-term results of the LIPSIA Yukon trial which compared the polymer-free sirolimus-eluting Yukon Choice stent with the polymer-based paclitaxel-eluting Taxus Liberté stent in this subpopulation. At 9 months, the Yukon Choice stent failed to show non-inferiority in terms of the primary end point late lumen loss, while no significant difference in clinical outcome was detected.

Methods And Results: The LIPSIA Yukon trial randomized 240 patients with diabetes mellitus to a polymer-free sirolimus eluting stent (Yukon Choice, Translumina) versus a polymer-based paclitaxel-eluting stent (Taxus Liberté, Boston Scientific). Clinical follow-up was conducted with a standardized telephone follow-up and all events were centrally adjudicated. Follow-up was available for 98.3% of patients after a median of 5.0 years. The incidence of all-cause death (16.9% versus 14.0%, P = 0.67), respectively definite or presumed cardiovascular death (7.6% versus 8.8%, P = 0.94) were similar in the Yukon Choice and the Taxus Liberté group. There were no significant differences in the rates of myocardial infarction (9.3% versus 7.9%, P = 0.88), definite stent thrombosis (0.8% versus 0.9%, P = 1.0), target lesion revascularization (15.3% versus 15.8%, P = 1.0), target vessel revascularization (18.6% versus 23.7%, P = 0.44), non-target vessel revascularization (18.6% versus 26.3%, P = 0.21), and stroke (3.4% versus 4.4%, P = 0.96) between patients assigned to the Yukon Choice and the Taxus Liberté stent.

Conclusion: At 5 years of follow-up, clinical outcome was similar between the polymer-free sirolimus-eluting Yukon Choice stent and the polymer-based paclitaxel-eluting Taxus Liberté stent.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.25131DOI Listing

Publication Analysis

Top Keywords

yukon choice
24
taxus liberté
20
polymer-based paclitaxel-eluting
16
polymer-free sirolimus-eluting
12
patients diabetes
12
diabetes mellitus
12
lipsia yukon
12
yukon trial
12
choice stent
12
stent
11

Similar Publications

Despite widespread plans to embed justice, equity, decolonization, indigenization, and inclusion (JEDII) into universities, progress toward deeper, systemic change is slow. Given that many community-based conservation (CBC) scholars have experience creating enduring social change in diverse communities, they have transferable skills that could help embed JEDII in universities. We synthesized the literature from CBC and examined it through the lens of self-determination theory to help identify generalizable approaches to create resilient sociocultural change toward JEDII in universities.

View Article and Find Full Text PDF

Competition for resources and space can drive forage selection of large herbivores from the bite through the landscape scale. Animal behaviour and foraging patterns are also influenced by abiotic and biotic factors. Fine-scale mechanisms of density-dependent foraging at the bite scale are likely consistent with density-dependent behavioural patterns observed at broader scales, but few studies have directly tested this assertion.

View Article and Find Full Text PDF

Aim: The aim of this study was to assess the safety and efficacy profile of a newer generation biodegradable DES, the Yukon Choice PC Elite with a temperature controlling mechanism, in patients with acute coronary syndrome (ACS).

Methods: This prospective multi-center study (PIONEER Registry) was conducted in an Indian ACS population, therefore providing data in real world clinical practice. Patients with ACS underwent DES implantation in de novo native-vessel coronary lesions with the Yukon Choice PC Elite biodegradable polymer DES and were followed up for a year.

View Article and Find Full Text PDF

Executive functions including working memory (WM) and attention are altered following Cannabis exposure in humans. To test for similar effects in a rodent model, we exposed adult male rats to acute Cannabis smoke before testing them on touchscreen-based tasks that assess these executive processes. The trial-unique, delayed nonmatching-to-location (TUNL) task was used to evaluate WM, task performance at different spatial pattern separations, and response latencies.

View Article and Find Full Text PDF

In-stent restenosis and stent thrombosis are the major concerns while choosing a coronary stent. This single-centre, retrospective study evaluated the one and three-year clinical outcomes following implantation of Yukon Choice Flex (YCF) sirolimus-eluting stent. A total of 168 consecutive patients with 217 lesions underwent stenting with YCF stent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!