Diaphragm depth in normal subjects.

Muscle Nerve

Department of Physical Medicine and Rehabilitation, Mayo Clinic and Foundation, Rochester, Minnesota, 55905, USA.

Published: May 2014

Introduction: Needle electromyography (EMG) of the diaphragm carries the potential risk of pneumothorax. Knowing the approximate depth of the diaphragm should increase the test's safety and accuracy.

Methods: Distances from the skin to the diaphragm and from the outer surface of the rib to the diaphragm were measured using B mode ultrasound in 150 normal subjects.

Results: When measured at the lower intercostal spaces, diaphragm depth varied between 0.78 and 4.91 cm beneath the skin surface and between 0.25 and 1.48 cm below the outer surface of the rib. Using linear regression modeling, body mass index (BMI) could be used to predict diaphragm depth from the skin to within an average of 1.15 mm.

Conclusions: Diaphragm depth from the skin can vary by more than 4 cm. When image guidance is not available to enhance accuracy and safety of diaphragm EMG, it is possible to reliably predict the depth of the diaphragm based on BMI.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mus.23953DOI Listing

Publication Analysis

Top Keywords

diaphragm depth
16
diaphragm
10
depth diaphragm
8
outer surface
8
surface rib
8
depth skin
8
depth
5
depth normal
4
normal subjects
4
subjects introduction
4

Similar Publications

This study addresses the challenges of electromagnetic interference and unstable signal transmission encountered by traditional sensors in detecting partial discharge (PD) within stator slots of large motors. A novel Extrinsic Fabry-Perot Interferometer (EFPI) sensor with a vibration-coupling air gap was designed to enhance the narrowband resonant detection sensitivity for PD ultrasonic signals by optimizing the diaphragm structure and coupling interface. The sensor features a quartz diaphragm with a thickness of 20 μM, an effective constrained radius of 0.

View Article and Find Full Text PDF

A small cavity for detecting sound-induced flow.

J Acoust Soc Am

January 2025

Department of Mechanical Engineering, Binghamton University, Binghamton, New York 13902, USA.

A study is presented of a method for creating an acoustic flow sensor that is generally compatible with current silicon microfabrication processes. An aim of this effort is to obtain a design consisting of a minimal departure from the existing designs employed in mass-produced silicon microphones. Because the primary component in all of these microphones is the cavity behind the pressure-sensing diaphragm, we begin with a study of the acoustic particle velocity within a cavity in a planar surface.

View Article and Find Full Text PDF
Article Synopsis
  • The excavation of large tunnel portals can lead to significant engineering challenges, necessitating a thorough understanding of construction mechanics and careful scheme selection.
  • In analyzing a six-lane expressway tunnel in Southwest China, three excavation methods were compared: the three-bench seven-step method, the central diaphragm method (CDM), and the double side drift method (DSDM).
  • Results showed that asymmetrical loads affected rock deformation, with both CDM and DSDM providing better stability and less deformation by adapting the excavation sequence for optimal results.
View Article and Find Full Text PDF

Intrinsic Muscle Stem Cell Dysfunction Contributes to Impaired Regeneration in the mdx Mouse.

J Cachexia Sarcopenia Muscle

February 2025

Sprott Centre for Stem Cell Research, Regenerative Medicine Program, Ottawa Hospital Research Institute, Ottawa, Canada.

Background: Duchenne muscular dystrophy (DMD) is a devastating disease characterized by progressive muscle wasting that leads to diminished lifespan. In addition to the inherent weakness of dystrophin-deficient muscle, the dysfunction of resident muscle stem cells (MuSC) significantly contributes to disease progression.

Methods: Using the mdx mouse model of DMD, we performed an in-depth characterization of disease progression and MuSC function in dystrophin-deficient skeletal muscle using immunohistology, isometric force measurements, transcriptomic analysis and transplantation assays.

View Article and Find Full Text PDF

The stress status of a soil pressure cell placed in soil is very different from its stress state in a uniform fluid medium. The use of the calibration coefficient provided by the soil pressure cell manufacturer will produce a large error. In order to improve the measurement accuracy of the interface-type earth pressure cell placed in soil, this paper focuses on a single-membrane resistive earth pressure cell installed on the surface of a structure, analyzing the influence of loading and unloading cycles, the thickness and particle size of the sand filling, and the depth of the earth pressure cell inserted in the structure on the calibration curve and matching error, which were analyzed through calibration tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!