Cardiac CT angiography (cCTA) has become an established method for the assessment of congenital heart disease. However, the potential harmful effects of ionizing radiation must be considered, particularly in younger, more radiosensitive patients. In this study, we sought to assess the temporal change in radiation doses from pediatric cCTA during an 8-year period at a tertiary medical center. This retrospective study included all patients ≤18 years old who were referred to electrocardiography (ECG)-gated cCTA for the assessment of congenital heart disease or inflammatory disease (Kawasaki disease) from November 2004 to September 2012. During the study period, 95 patients were scanned using 3 different scanner models-64-slice multidetector CT (64-MDCT) and first- (64-DSCT) and second-generation (128-DSCT) dual-source CT-and 3 scan protocols-retrospective ECG-gated helical scanning (RG), prospective ECG-triggered axial scanning (PT), or prospective ECG-triggered high-pitch helical scanning (HPH). Effective dose (ED) was calculated with the dose length product method with a conversion factor (k) adjusted for age. ED was then compared among scan protocols. Image quality was extracted from clinical cCTA reports when available. Overall, 94 % of scans were diagnostic (80 % for 64-slice MDCT, 93 % for 64-slice DSCT, and 97 % for 128-slice DSCT).With 128-DSCT, median ED (1.0 [range 0.6-2.0] mSv) decreased by 85.8 % and 66.8 % compared with 64-MDCT (6.8 [range 2.9-13.6] mSv) and 64-DSCT (2.9 [range 0.9-4.1] mSv), respectively. With HPH, median ED (0.9 [range 0.6-1.8] mSv) decreased by 59.4 % and 85.4 % compared with PT (2.2 [range 0.9-3.4] mSv) and RG (6.1 [range 2.5-10.6] mSv). cCTA can now be obtained at very low radiation doses in pediatric patients using the latest dual-source CT technology in combination with prospective ECG-triggered HPH acquisition.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-013-0758-5DOI Listing

Publication Analysis

Top Keywords

prospective ecg-triggered
12
tertiary medical
8
medical center
8
assessment congenital
8
congenital heart
8
heart disease
8
radiation doses
8
doses pediatric
8
helical scanning
8
scanning prospective
8

Similar Publications

Background: The assessment of left ventricular (LV) systolic function and quantification of LV ejection fraction (EF) in patients with atrial fibrillation (AF) can be difficult. We previously demonstrated that LV volume changes over the 100 ms of systole (LVEF) can be used as a measure of LV systolic function.

Objective: We sought to evaluate the applicability of LVEF in AF patients.

View Article and Find Full Text PDF

Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a novel circular PFA catheter in comparison to an established PFA system in a real-world clinical setting.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the radiation dose reduction potential of a heart rate-independent dual-focused scan method for CT imaging in children with congenital heart disease (CHD), comparing it to traditional heart rate-dependent scans.
  • It involved 1,252 pediatric CT exams, using propensity score matching to control for age and sex while analyzing CT radiation dose, image noise, and quality metrics.
  • Results showed that dual-focused and single-extended scans had higher radiation doses compared to single-focused scans, but achieved similar image quality, with the dual-focused option being more effective at lower heart rates.
View Article and Find Full Text PDF

Impact of an institutional process change adopting end-systolic coronary CTA acquisition and automated dose selection on patient throughput and image quality.

J Cardiovasc Comput Tomogr

October 2024

Division of Cardiovascular Medicine, Department of Medicine, University of Virginia School of Medicine, Charlottesville, VA, USA; Division of Noninvasive Cardiovascular Imaging, Department of Radiology and Medical Imaging, University of Virginia School of Medicine, Charlottesville, VA, USA. Electronic address:

Article Synopsis
  • Guidelines suggest using ECG-triggered mid-diastolic CCTA after heart rate optimization for better image quality, but switching to prospective end-systolic acquisition may reduce motion artifacts and the need for beta-blockers.
  • An institutional change in January 2023 was made to adopt an algorithmic approach using prospective end-systolic acquisition without routine beta-blocker use, and image quality was assessed over three phases using a specific scoring model.
  • Results showed that after the process change, the median appointment time significantly decreased, indicating improved efficiency in performing CCTAs while maintaining image quality.
View Article and Find Full Text PDF

Background: Prospective ECG-triggered cardiac computed tomography (CT) imaging limits the ability to assess left ventricular (LV) ejection fraction (EF). We previously developed a new index derived from LV volume changes over 100 ​ms during systole (LVEF) as a surrogate of LV function in patients undergoing prospective ECG-triggered cardiac CT. We sought to evaluate the prognostic value of LVEF.

View Article and Find Full Text PDF