Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.

Biol Res Nurs

Núcleo de Estudos em Epidemiologia do Envelhecimento (NEPE), Departamento de Saúde, Universidade Estadual do Sudoeste da Bahia, Jequié, Bahia, Brazil Departamento de Educação Física, Centro de Desportos, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil.

Published: July 2014

This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1099800413495953DOI Listing

Publication Analysis

Top Keywords

total cholesterol
28
accutrend system
12
blood variables
12
glucose
8
glucose total
8
lin's coefficient
8
coefficient glucose
8
total
7
cholesterol
7
triglycerides
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!