A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Distinction between a transgenic and a conventional common bean genotype by 1H HR-MAS NMR. | LitMetric

Distinction between a transgenic and a conventional common bean genotype by 1H HR-MAS NMR.

Food Chem

Instituto de Química, Universidade Federal de Goiás, C.P. 131, 74001-970 Goiânia, GO, Brazil.

Published: December 2013

In this work, it is proposed a methodology which allows to differentiate a conventional and a specific transgenic common beans, grown in greenhouse or under field conditions, based on modifications in chemical composition using (1)H HR-MAS NMR. It is demonstrated that the influence of typical variables from field planting conditions had no significant influence on the ability to set apart transgenic from conventional. This methodology was corroborated by multivariate data analysis of the (1)H NMR and IR spectra. This study also points out the simplicity of using the HR-MAS NMR technique for food analyses. The measurement is highly simplified because it does not require any pretreatment of the sample apart from the addition of a small amount of D2O necessary to produce homogeneous dough and a field frequency lock. Moreover, due to the high concentration of the sample, measurement time in HR-MAS NMR is very short.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2013.05.123DOI Listing

Publication Analysis

Top Keywords

hr-mas nmr
16
transgenic conventional
8
nmr
5
distinction transgenic
4
conventional common
4
common bean
4
bean genotype
4
hr-mas
4
genotype hr-mas
4
nmr work
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!