A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of polycyclic aromatic hydrocarbons in smoked fish samples by a new microextraction technique and method optimisation using response surface methodology. | LitMetric

Determination of polycyclic aromatic hydrocarbons in smoked fish samples by a new microextraction technique and method optimisation using response surface methodology.

Food Chem

Department of Food Science and Technology, Faculty of Nutrition Science, Food science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Published: December 2013

Microwave-assisted extraction coupled with dispersive liquid-liquid microextraction as a recently introduced method was applied to determine polycyclic aromatic hydrocarbons in Iranian smoked fish. The results showed that the interaction of hydrolysing solution volume with ethanol ratio, volumes of extracting and disperser solvent is significant in the obtained model. Optimized conditions were: a hydrolysing solution volume 10 ml with 50% ethanol, a pH of 5, and extracting and disperser solvent volumes of 150 and 500 μl respectively. The level of 16 polycyclic aromatic hydrocarbons (PAHs) was determined in 80 smoked fish consisting of four species. The contamination of benzo[a]pyrene in all samples except three was below the European Commission's maximum level of 2 μg kg(-1) for smoked fish, while the ∑4 PAHs (benzo[a]pyrene, chrysene, benzo[a]anthracene and benzo[b]fluoranthene) were between 3 and 12 μg kg(-1) wet weight in all samples. Of the species examined, Hypophthalmichthys molitrix had the highest PAHs (∑16).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2013.05.065DOI Listing

Publication Analysis

Top Keywords

smoked fish
16
polycyclic aromatic
12
aromatic hydrocarbons
12
hydrolysing solution
8
solution volume
8
extracting disperser
8
disperser solvent
8
μg kg-1
8
determination polycyclic
4
smoked
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!