Purpose: The objective of this study was to prospectively verify if diffusion-weighted magnetic resonance (DwMR)-related parameters such as perfusion fraction (f) and slow diffusion coefficient (D), according to Le Bihan theory, are more effective than apparent diffusion coefficient (ADC) for classification and characterization of the more frequent focal liver lesions (FLLs) in noncirrhotic liver.

Methods: Sixty-seven patients underwent standard liver magnetic resonance imaging (MRI) and free-breath multi-b DwMR study. Two regions of interest were defined by 2 observers, including 1 FLL for each patient (21 hemangiomas, 21 focal nodular hyperplasias, 25 metastases) and part of surrounding parenchyma, respectively. For every FLL, D, f, and ADC were estimated both as absolute value and as ratio between FLL and surrounding parenchyma by fitting the reduced equation of the bicompartmental model to experimental data; t test, analysis of variance, and receiver operating characteristic analysis were performed.

Results: t Test showed significant differences in ADClesion, f lesion, D lesion, ADCratio, and D ratio values between benign and malignant FLLs, more pronounced for ADClesion (P < 0.0009) and ADCratio (P = 0.001). Applying cutoff values of 1.55 × 10  mm/s (ADClesion) and 0.89 (ADCratio), the DwMR study presented sensitivities and specificities, respectively, of 84% and 80% (for ADClesion), 72% and 80% (ADCratio).

Conclusions: Apparent diffusion coefficient (by fitting procedures) better performs than do D and f in FLL classification, especially when its values are less than 1.30 or greater than 2.00 × 10  mm/s.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RCT.10.1097/RCT.0b013e3182951fe9DOI Listing

Publication Analysis

Top Keywords

diffusion coefficient
12
focal liver
8
classification characterization
8
diffusion-weighted magnetic
8
magnetic resonance
8
apparent diffusion
8
dwmr study
8
surrounding parenchyma
8
10  mm/s
8
liver lesion
4

Similar Publications

Carpal tunnel syndrome (CTS) is a common peripheral nerve entrapment disorder that is diagnosed using clinical signs and symptoms and confirmed via nerve conduction studies (NCSs). While NCS is a semi-invasive procedure, magnetic resonance imaging (MRI) is a non-invasive diagnostic tool that detects macroscopic nerve abnormalities and evaluates a patient's surgical or medication treatment options. This study assessed magnetic resonance neurography (MRN)'s diagnostic and grading value by comparing it to electrodiagnostic studies in patients with CTS and healthy individuals.

View Article and Find Full Text PDF

Primary uterine non-Hodgkin lymphoma (NHL) is rarely reported, as its incidence is extremely low. We describe a 72 year old patient with primary uterine non-Hodgkin's lymphoma stage IV, diffuse B-cell large cells, who responded well to cytotoxic chemotherapy (R-CHOP). Radiological investigations exhibited certain characteristics, including magnetic resonance T2 weighted imaging, enhanced scanning, diffusion weighted imaging and apparent diffusion coefficient values.

View Article and Find Full Text PDF

The hyaline-vascular variant of Castleman disease (HVCD) is relatively uncommon and demonstrates no specific clinical or laboratory findings; therefore, its preoperative diagnosis warrants a radiological evaluation. This study aimed to review imaging findings of HVCD, focusing on perilesional fat stranding and fatty proliferation. Patients with a pathologically confirmed HVCD diagnosis who had undergone CT were recruited from five hospitals from January 2000 to March 2023.

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the performance of multiparametric magnetic resonance imaging (mpMRI) radiomic feature-based machine learning (ML) models in classifying the Gleason grade group (GG) of prostate cancer.

Methods: In this retrospective study, a total of 203 patients with histopathologically confirmed prostate cancer who underwent mpMRI before prostate biopsy were included. After manual segmentation, radiomic features (RFs) were extracted from T2-weighted, apparent diffusion coefficient, and high b-value diffusion-weighted magnetic resonance imaging (DWMRI).

View Article and Find Full Text PDF

Design and Regulation of Anthraquinone's Electrochemical Properties in Aqueous Zinc-Ion Batteries via Benzothiadiazole and Its Dinitro Derivatives.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, and Department of Macromolecular Science and Engineering, School of Chemistry and Chemical Engineering, Heilongjiang University, Harbin 150080, P. R. China.

Organic cathode materials are widely considered as highly promising for aqueous zinc-ion batteries (AZIBs) due to their tunable properties, low cost, and ease of processing and synthesis. Benzothiadiazoles have demonstrated significant potential as organic electrode materials in AZIBs, owing to their strong electron-accepting capabilities and the presence of multiple reversible redox sites in anthraquinone. In this study, we designed a polymer, poly(2-methyl-6-(7-methyl-5,6-dinitrobenzo[][1,2,5]thiadiazol-4-yl)anthracene-9,10-dione) (PBDQ), with multielectron transfer capability through a copolymerization approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!