New technology offers potential advantages in physically demanding environments where convenience and comfort are important and accurate and reliable data collection is challenging. Nevertheless, it is important to validate the accuracy and reliability of such biological monitoring systems (BMS) before they are adopted. The purpose of this investigation was to assess the concurrent validity of a new heart rate monitor across a range of exercise intensities and with a large and diverse group of male subjects in a large cohort with diverse physical fitness characteristics. Seventy-five men (age, 23 ± 4 years; height, 181 ± 8 cm; body mass, 83 ± 12 kg; estimated V[Combining Dot Above]O2peak, 3.16 ± 0.63 [L·min]) volunteered and completed a graded cycle ergometer exercise protocol while heart rate was continuously monitored before, during, and after exercise with the new device (Armour39) and the gold standard (electrocardiogram). The 2-minute stages included sitting, standing, and cycling with 35 W increments until volitional fatigue. The coefficient of determination between mean heart rate values at each stage was R = 0.99, whereas Pearson correlations (r) at each stage were ≥ 0.99. Heart rates during exercise were typically within 1 beat of each other. The Armour39 BMS, therefore, is an acceptable means for the valid and reliable determination of heart rate under various bodily positions and levels of exertion, including maximal exercise intensity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0b013e3182a16d38 | DOI Listing |
Trials
December 2024
Department of Cardiology, The Heart Centre, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark.
Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.
View Article and Find Full Text PDFCardiovasc Revasc Med
December 2024
Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:
Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.
View Article and Find Full Text PDFBMJ Open
December 2024
Department of Exercise and Sport Science, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
Background: Sedentary behaviour (SB) is detrimental to cardiometabolic disease (CMD) risk, which can begin in young adulthood. To devise effective SB-CMD interventions in young adults, it is important to understand which context-specific SB (CS-SB) are most detrimental for CMD risk, the lifestyle behaviours that cluster with CS-SBs and the socioecological predictors of CS-SB.
Methods And Analysis: This longitudinal observational study will recruit 500 college-aged (18-24 years) individuals.
Clin Chim Acta
December 2024
Southwest Finland Wellbeing Services County, Turku University Hospital Services, Geriatric Medicine, 20521 Turku, Finland; Faculty of Medicine, Department of Clinical Medicine, Unit of Geriatric Medicine, University of Turku and Turku University Hospital, 20700 Turku, Finland.
Background: Cardiac troponin T (cTnT) and N-terminal B-type natriuretic propeptide (proBNP) are mainly used as biomarkers to diagnose specific conditions of the heart, but they also have predictive ability. Our aim was to study their associations with cardiovascular and all-cause mortality in an older population in non-acute conditions.
Methods: A population-based study with a ten-year follow-up.
Neuropharmacology
December 2024
Department of Experimental Physiology and Pathophysiology, Medical University of Białystok, ul. Mickiewicza 2A, 15-222 Białystok, Poland.
Although angiotensin 1-7 (Ang 1-7) and its role as a part of the "protective" axis of the renin-angiotensin system are well described in the literature, the mechanisms of its angiotensin II-like pressor and tachycardic effects following its acute central administration are not fully understood. It was the aim of the present study to examine which receptors contribute to the aforementioned cardiovascular effects. Ang 1-7 and antagonists for glutamate, GABA, vasopressin, thromboxane A (TP), α-adrenergic, and P2X purinoceptors or modulators of oxidative stress were injected into the paraventricular nucleus of the hypothalamus (PVN) of urethane-anesthetized male Wistar rats.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!