A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fixed energy X-ray absorption voltammetry. | LitMetric

In this paper, the fixed energy X-ray absorption voltammetry (FEXRAV) is introduced. FEXRAV represents a novel in situ X-ray absorption technique for fast and easy preliminary characterization of electrode materials and consists of recording the absorption coefficient at a fixed energy while varying at will the electrode potential. The energy is chosen close to an X-ray absorption edge, in order to give the maximum contrast between different oxidation states of an element. It follows that any shift from the original oxidation state determines a variation of the absorption coefficient. Although the information given by FEXRAV obviously does not supply the detailed information of X-ray absorption near edge structure (XANES) or extended X-ray absorption fine structure (EXAFS), it allows to quickly map the oxidation states of the element under consideration within the selected potential windows. This leads to the rapid screening of several systems under different experimental conditions (e.g., nature of the electrolyte, potential window) and is preliminary to more deep X-ray absorption spectroscopy (XAS) characterizations, like XANES or EXAFS. In addition, the time-length of the experiment is much shorter than a series of XAS spectra and opens the door to kinetic analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac401414vDOI Listing

Publication Analysis

Top Keywords

x-ray absorption
28
fixed energy
12
absorption
9
energy x-ray
8
absorption voltammetry
8
absorption coefficient
8
absorption edge
8
oxidation states
8
states element
8
x-ray
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!