Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A left atrial pressure (LAP) monitoring system was developed for guiding the management of patients with heart failure. The LAP sensor is implanted into the left atrium via transseptal catheterization and affixed to the interatrial septum by nitinol anchors. The long-term safety of permanent implantation of the LAP sensor in patients was evaluated based on the comparative pathology in animals. Tissue specimens of the LAP sensor from 7 patients, 49 canines, and 14 ovine were examined for thrombosis and tissue overgrowth. Implant duration ranged from 22 to 1,686 days. Gross examination showed minimal-to-moderate tissue overgrowth with no evidence of migration, erosion, or perforation. There was no excessive host-to-device reaction or active thrombogenesis in any of the subjects that followed the antithrombotic therapy protocol. Micro-computed tomography scanning confirmed the structural integrity of the device. Low vacuum scanning electron microscopy and histology showed neoendocardial tissue overgrowth with no inflammation or fibrin. The pathology of both animal models was found to closely approximate the pathology in humans and favorably supports the long-term safety of the device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAT.0b013e31829bdffd | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!