A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sensitivity improved plasmonic gold nanoholes array biosensor by coupling quantum-dots for the detection of specific biomolecular interactions. | LitMetric

Sensitivity improved plasmonic gold nanoholes array biosensor by coupling quantum-dots for the detection of specific biomolecular interactions.

Biosens Bioelectron

Key Laboratory for Special Functional Materials of Ministry of Education, Henan University, Kaifeng 475004, PR China.

Published: December 2013

In this paper, we focused on the large-scale fabrication of gold nanoholes array capable of supporting surface plasmonic resonance (SPR) via the developed nanosphere lithography (NSL) technique, which could be used as high performance biosensor for the detection of specific streptavidin-biotin interactions. Direct UV-vis absorption mode measurement was used to monitor the SPR peak shift. For the better immobilization of biotin, the surface of gold nanoholes array was functionalized with 3-mercaptopropyl trimethoxysilane (MPTS) and 3-aminopropyl triethoxysilane (APTES). After the streptavidin binding to the biotin, the SPR peak position showed an 11 nm wavelength shift due to the refractive index change caused by the biotin-streptavidin binding. The sealing treatment was performed by using bovine serum albumin (BSA) to eliminate the influences of nonspecific adsorption for more accurate detection. Interestingly, the detection sensitivity of the gold nanoholes array could be further enhanced by coupling the water-soluble CdSe/ZnS quantum dots (QDs), which showed four-fold improvement in detection sensitivity as compared to the gold nanoholes array biosensor without the coupling of QDs. The mechanisms for the enhancement of detection sensitivity were also discussed. This would provide new capabilities for the highly sensitive measurements of biomolecular binding.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2013.06.023DOI Listing

Publication Analysis

Top Keywords

gold nanoholes
20
nanoholes array
20
detection sensitivity
12
array biosensor
8
biosensor coupling
8
detection specific
8
spr peak
8
detection
6
gold
5
nanoholes
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!