A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A sensitive DNA biosensor based on a facile sulfamide coupling reaction for capture probe immobilization. | LitMetric

A novel DNA biosensor was fabricated through a facile sulfamide coupling reaction. First, the versatile sulfonic dye molecule of 1-amino-2-naphthol-4-sulfonate (AN-SO3(-)) was electrodeposited on the surface of a glassy carbon electrode (GCE) to form a steady and ordered AN-SO3(-) layer. Then the amino-terminated capture probe was covalently grafted to the surface of SO3(-)-AN deposited GCE through the sulfamide coupling reaction between the amino groups in the probe DNA and the sulfonic groups in the AN-SO3(-). The step-by-step modification process was characterized by electrochemistry and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy. Using Ru(NH3)6(3+) as probe, the probe density and the hybridization efficiency of the biosensor were determined to be 3.18×10(13) strands cm(-2) and 86.5%, respectively. The hybridization performance of the biosensor was examined by differential pulse voltammetry using Co(phen)3(3+/2+) (phen=1,10-phenanthroline) as the indicator. The selectivity experiments showed that the biosensor presented distinguishable response after hybridization with the three-base mismatched, non-complementary and complementary sequences. Under the optimal conditions, the oxidation peak currents of Co(phen)3(3+/2+) increased linearly with the logarithm values of the concentration of the complementary sequences in the range from 1.0×10(-13)M to 1.0×10(-8)M with a regression coefficient of 0.9961. The detection limit was estimated to be 7.2×10(-14)M based on 3σ.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2013.06.018DOI Listing

Publication Analysis

Top Keywords

sulfamide coupling
12
coupling reaction
12
dna biosensor
8
facile sulfamide
8
capture probe
8
complementary sequences
8
biosensor
5
probe
5
sensitive dna
4
biosensor based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!