A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Fabrication of two dimensional silver cavity array and its application in SERS detection]. | LitMetric

[Fabrication of two dimensional silver cavity array and its application in SERS detection].

Guang Pu Xue Yu Guang Pu Fen Xi

School of Chemistry and Chemical Engineering, Nantong University, Nantong 226019, China.

Published: April 2013

The highly ordered two dimensional micro-/nano-sized silver cavity was fabricated by galvanostatic multistep method using ordered arrays of close-packed 700 nm diameter polystyrene spheres as templates. The morphology and the surface plasmon resonance of this silver cavity array were characterized by scanning electron microscope and reflectance UV-Vis spectra, and surface-enhanced Raman scattering (SERS) spectra of p-aminothiophenol (PATP) and Rhodamine 6G (R6G) on as-prepared substrate were also studied. The results show that: the depth of cavities can be easily regulated through varying the parameters of the electrochemical deposition. As SERS substrates for the detection of PATP molecules, the two dimensional Ag cavity arrays exhibit excellent performance and the enhancement factors can be as high as the 10(7) order. In addition to the high-intensity enhancement, it is also found that the SERS spectra are highly reproducible on this Ag cavity arrays. The relative standard deviation of the peak intensity of PATP molecules at 1 077 cm(-1) was calculated to be 8.4%. The as-prepated substrate can be used for the quantitative detection of R6G, and the detection limit reaches as low as 0.1 ng x mL(-1).

Download full-text PDF

Source

Publication Analysis

Top Keywords

silver cavity
12
cavity array
8
sers spectra
8
patp molecules
8
cavity arrays
8
cavity
5
[fabrication dimensional
4
dimensional silver
4
array application
4
sers
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!