Body mass index, cholecystitis, cholelithiasis, pancreatitis and imaging of common bile duct stones.

Am J Med Sci

Departments of Radiology (GC, EY), Gastroenterology (SG, ZC), and General Surgery (ET), Baskent University Faculty of Medicine, Konya; and Department of Statistics and Computer Science (MA), Baskent University Faculty of Science and Letters, Ankara, Turkey.

Published: May 2014

Purpose: Studies to date have not investigated whether body mass index (BMI) affects the sensitivity and specificity of magnetic resonance cholangiopancreatography (MRCP). The purpose of this study was to investigate the effect of BMI and also concomitant pancreatitis, cholecystitis and cholelithiasis on the sensitivity and specificity of MRCP.

Materials And Methods: Between January 2004 and December 2011, 185 patients were included in the study and divided into 3 groups according to BMI as normal, overweight or obese. Both MRCP and endoscopic retrograde cholangiopancreatography (ERCP) were performed in all patients. ERCP was accepted as the "gold standard." The accuracy, sensitivity and specificity values of the 3 groups were calculated to determine any effects on the results of the MRCP.

Results: Before separating into groups according to BMI, the statistical results for MRCP in the detection of stone disease were as follows: specificity 74.3%, sensitivity 81.7% and accuracy 79%. After dividing the patients into 3 groups according to BMI, the specificity of stone detection with MRCP in the normal-weight group was 93.8% but decreased to 65.5% in the overweight group and to 72% in the obese group. The sensitivity of stone detection with MRCP in the normal-weight group was 85.2% but decreased to 75% in the overweight group and increased to 88.9% in the obese group. The accuracy was 88.3% in the normal-weight group but decreased to 71.6% in the overweight group and to 81.9% in the obese group.

Conclusion: Our study showed that MRCP performance was decreased in the overweight and obese groups.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAJ.0b013e318296a6feDOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
12
groups bmi
12
normal-weight group
12
overweight group
12
body mass
8
cholecystitis cholelithiasis
8
overweight obese
8
stone detection
8
detection mrcp
8
mrcp normal-weight
8

Similar Publications

Objective: To conduct a meta-analysis assessing the diagnostic performance of the node reporting and data system (Node-RADS) for detecting lymph node (LN) invasion.

Method: We performed a systematic literature search of online scientific publication databases from inception up to July 31, 2024. We used the quality assessment of diagnostic accuracy studies-2 (QUADAS-2) to assess the study quality, and heterogeneity was determined by the Q-test and measured with I statistics.

View Article and Find Full Text PDF

Objectives: Artificial intelligence (AI) software including Brainomix "e-CTA" which detect large vessel occlusions (LVO) have clinical potential. We hypothesised that in real world use where prevalence is low, its clinical utility may be overstated.

Methods: In this single centre retrospective service evaluation project, data sent to Brainomix from a medium size acute National Health Service (NHS) Trust hospital between 1/3/2022-1/3/2023 was reviewed.

View Article and Find Full Text PDF

Objectives: To evaluate relationship between sFlt-1/PlGF ratio, clinical characteristics and outcomes of pre-eclampsia.

Material And Methods: Retrospective analysis of 29 pregnant women with pre-eclampsia who had measured sFlt-1/PlGF ratio was conducted using electronic medical records from Obstetrics and Perinatology ward of University Hospital in Cracow.

Results: Women median age: 33.

View Article and Find Full Text PDF

Multi-diagnostic chest-worn patch to detect obstructive sleep apnea and cardiac arrhythmias.

J Clin Sleep Med

January 2025

Division of Sleep Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.

Study Objectives: Evaluate the performance of the SANSA device to simultaneously assess obstructive sleep apnea (OSA) and cardiac arrhythmias.

Methods: Participants suspected or known to have OSA underwent polysomnography (PSG) while wearing SANSA. SANSA's algorithm was trained using 86 records and tested on 67 to evaluate training bias.

View Article and Find Full Text PDF

Objectives: Knee Osteoarthritis (OA) is one of the most frequently encountered conditions in orthopedic practice. This study aimed to validate the Knee Intake Patient Survey (KIPS), a short-form questionnaire designed to assist in the initial diagnosis and treatment stratification for knee OA.

Methods: Patient intake survey results from a single adult reconstruction clinic were retrospectively analyzed alongside clinical diagnoses and treatment recommendations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!