Comparison of keratometric values and corneal eccentricity.

Coll Antropol

Faculty of Medicine, Department of Non-medical Branch, Brno, Czech Republic.

Published: April 2013

The aim of this work is to compare the findings of keratometric values and their differences at various refractive errors. The eccentricity of the cornea in the sense compared to the possible influence of refraction of the eye is topographically observed. Groups of myopia, hyperopia and emmetropia (as a control group) are always represented in total 600 eyes. The studied cohort in total of 300 clients enrolled. Autorefraktokeratometer with Placido disc was used to measure the steepest and the flattest meridian to determine the corneal eccentricity. Group I consisted of 100 myopes, 35 men and 65 women, average age 37.3 years. Objective refraction--sphere: -2.9 D, cylinder: -0.88 D. Keratometry in this group is in the steepest meridian 7.62 mm and the flattest meridian is 7.76 mm. The eccentricity was 0.37. Group II consisting of 100 hyperopic subjects, 40 men and 60 women, average age 61.6 years. Objective refraction--sphere: +2.71 D, cylinder: -1.0 D. Keratometric measurement looks as follows: the steepest meridian is 7.67 mm, the flattest meridian then is 7.81 mm. The value of the eccentricity is 0.37. The third group III consists of 100 emetropic subjects, then clients without refractive errors who achieve without corrective aids Vmin = 1.0. This group is composed of 42 men and 58 women, mean age 41.4 years. Objective refraction--sphere: +0.32 D, cylinder: -0.28 D. The steepest meridian is 7.72 mm the flattest meridian then 7.83 mm. The eccentricity is represented by the observed values of 0.36. Keratometry as well as topography are fundamental methods of corneal anterior surface measurement. Their proportions are essential for the proper parameters selection especially in case of contact lenses as one of the possible means intended to correct refractive errors.

Download full-text PDF

Source

Publication Analysis

Top Keywords

flattest meridian
16
refractive errors
12
men women
12
years objective
12
objective refraction--sphere
12
steepest meridian
12
keratometric values
8
corneal eccentricity
8
women average
8
average age
8

Similar Publications

Intrastromal Corneal Ring Segments and Keratoconus Progression: A Case Series Study.

Eye Contact Lens

November 2024

Cornea Unit (B.B.-P.), Hospital Severo Ochoa, Madrid, Spain; Department of Ophthalmology (P.A.-V., R.C.-S., D.D.-V.), Department of Immunology, Ophthalmology and ENT, Faculty of Medicine, Universidad Complutense de Madrid (UCM) and IdISSC, Hospital Clínico San Carlos, Madrid, Spain; Department of Ophthalmology (O.R.-Q.), Hospital Clínico San Carlos and IdISSC, Madrid, Spain; and Department of Surgical and Clinical, Diagnostic and Pediatric Sciences (V.T.), Section of Ophthalmology, University of Pavia, IRCCS, Policlinico San Matteo, Pavia, Italy.

Objective: To assess keratoconus (KC) progression following the implant of intrastromal corneal ring segments (ICRSs) in young patients.

Materials And Methods: Retrospective, longitudinal, observational, controlled nonrandomized case series study. Keratoconus patients aged 25 years or younger who underwent uneventful ICRS surgery and completed at least 3 years of follow-up were enrolled.

View Article and Find Full Text PDF

Calculation of the total corneal astigmatism using the virtual cross cylinder method on the secondary principal plane of the cornea.

Sci Rep

February 2024

Department of Ophthalmology, Osaka Minato Central Hospital, Japan Community Health care Organization (JCHO), 1-7-1 Isoji, Minato-Ku, Osaka, 552-0003, Japan.

This study aimed to establish a virtual cross cylinder method to calculate the total corneal astigmatism by combining the anterior and posterior corneal astigmatism on the secondary principal plane of the cornea based on Gaussian optics. The meridian with the least refractive power, namely, the flattest meridian of the virtual cross cylinder of a ± 0.5 × C diopter, is set as the reference meridian, and the power (F) at an angle of φ between an arbitrary meridian and the reference meridian is defined as F(φ) =  - 0.

View Article and Find Full Text PDF

Scheimpflug Pentacam Tomography is becoming crucial in the diagnosis and monitoring of keratoconus, as well as in pre- and post-corneal refractive care, but there are still some inconsistencies surrounding its evidence base diagnostic outcome. Therefore, this study aimed at employing meta-analysis to systematically evaluate the keratometric, pachymetric, and pachymetric progression indices used in the diagnosis of Keratoconus. The review protocol was registered with PROSPERO (Identifier: CRD4202310058) and followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement.

View Article and Find Full Text PDF

Prediction of posterior elevation stability in keratoconus.

Front Bioeng Biotechnol

November 2023

Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China.

This study aimed to investigate the features of progressive keratoconus by means of machine learning. In total, 163 eyes from 127 patients with at least 3 examination records were enrolled in this study. Pentacam HR was used to measure corneal topography.

View Article and Find Full Text PDF

Study on Related Factors of the Treatment Zone After Wearing Paragon CRT and Euclid Orthokeratology Lenses.

Eye Contact Lens

December 2023

Department of Ophthalmology (S.K., Y.R., Xinyu Zhuang, Xiaofeng Zhang), The First Affiliated Hospital of Soochow University, Suzhou, China; and Department of Ophthalmology (Y.C., Xiaofeng Zhang), Dushu Lake Hospital Affiliated to Soochow University, Suzhou, China.

Objective: To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.

Methods: The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!