We present a case of a 9-month-old girl in whom malignant polymorphic ventricular tachycardia (VT) was successfully controlled by radiofrequency catheter ablation under guidance with a three-dimensional mapping system. The VTs originated from the left ventricular lateral wall, left ventricular anterior wall, and left ventricular apex. At least six types of VTs were documented during the electrophysiology study. All VTs were successfully controlled after two sessions of radiofrequency catheter ablation, and she was discharged from our hospital on propranolol, mexiletine, flecainide, and aprindine.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-013-0390-6DOI Listing

Publication Analysis

Top Keywords

radiofrequency catheter
12
catheter ablation
12
left ventricular
12
polymorphic ventricular
8
ventricular tachycardia
8
wall left
8
ventricular
5
successful control
4
control life-threatening
4
life-threatening polymorphic
4

Similar Publications

Incidence, Characteristics and Prognostic Significance of Early Recurrences Following Different Ablation Approaches for Persistent Atrial Fibrillation.

Heart Rhythm

December 2024

University of Melbourne, Melbourne, Victoria, Australia; Royal Melbourne Hospital, Melbourne, Victoria, Australia; Baker Heart and Diabetes Research Institute, Melbourne, Victoria, Australia. Electronic address:

Background: Early recurrence of atrial tachyarrhythmia (ERAT) is common following catheter ablation of atrial fibrillation (AF). The specific clinical and arrhythmia characteristics of ERAT influencing late recurrence risk in persistent AF is unclear. Additionally, the impact of different ablation strategies on the incidence and prognostic significance of ERAT remains unknown.

View Article and Find Full Text PDF

Catheter ablation-based management strategies for the drug-refractory electrical storm (ES) have been proven to abolish acute ventricular arrhythmic episodes and improve long-term outcomes. However, this effect is highly influenced by multiple independently acting factors, which, if identified and addressed, may allow a more tailored management to each particular case to improve results. This review synthesizes existing evidence concerning ES outcome predictors of patients undergoing ablation and introduces the role of novel scoring algorithms to refine risk stratification.

View Article and Find Full Text PDF

The Value of P-Wave Parameters Changes in Predicting Catheter Ablation Outcomes for Paroxysmal Atrial Fibrillation.

Ann Noninvasive Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.

Background: Pulmonary vein isolation (PVI) is the most promising management method for paroxysmal atrial fibrillation (PAF). The P wave in the electrocardiogram (ECG) represents atrial depolarization. This study aims to correlate P-wave parameters after PVI with outcomes.

View Article and Find Full Text PDF

Comparing pulsed field ablation with very high-power and high-power short-duration radiofrequency ablation for atrial fibrillation: a systematic review and meta-analysis.

J Interv Card Electrophysiol

December 2024

Section of Electrophysiology, Division of Cardiology, Department of Medicine, Rush University Medical Center, 1717 W Congress Pkwy/Suite 317 Kellogg, Chicago, IL, 60612, USA.

Background: Catheter ablation is a key treatment for atrial fibrillation (AF), with high-power, very high-power short-duration and pulsed field ablation (PFA) being efficient options. However, direct comparisons between these techniques are lacking.

Objective: We performed a systematic review and meta-analysis, which included predominantly observational studies (four retrospective and one prospective study), to compare PFA and High-power short-duration (HPSD) and very high-power short-duration (vHPSD) radiofrequency (RF) ablation in patients with AF.

View Article and Find Full Text PDF

Pulsed Field Ablation (PFA) is a new ablation method being rapidly adopted for treatment of atrial fibrillation, which shows advantages in safety and efficiency over radiofrequency and cryo-ablation. In this study, we used an in vivo swine model (10 healthy and 5 with chronic myocardial infarct) for ventricular PFA, collecting intracardiac electrograms, electro-anatomical maps, native T1-weighted and late gadolinium enhancement MRI, gross pathology, and histology. We used 1000-1500 V pulses, with 1-16 pulse trains to vary PFA dose.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!