A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of two dental registration-splint techniques for surgical navigation in cranio-maxillofacial surgery. | LitMetric

Evaluation of two dental registration-splint techniques for surgical navigation in cranio-maxillofacial surgery.

J Craniomaxillofac Surg

Clinic for Cranio-Maxillofacial Surgery (Head: K.W. Grätz), University Hospital Zurich, Frauenklinikstrasse 24, CH-8091 Zurich, Switzerland; Surgical Planning Laboratory (Head: R. Kikinis), Harvard Medical School, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115 USA. Electronic address:

Published: July 2014

Background: Surgical navigation requires precise registration of the pre-operative image dataset to the patient in the operation theatre. Different marker-based and marker-free registration techniques are available, each of them with advantages and disadvantages regarding precision and clinical handling. In this model study, the precision of two dental splint techniques for marker-based registration is analyzed.

Materials And Methods: A synthetic full-size human skull was registered with its cone beam computed tomography dataset using (a) a dentally-mounted "rapid" occlusal splint with five titanium screws directly attached to the splint, (b) an "extender", a dentally-mounted occlusal splint with similar fiducials fixed to an extension of the splint. The target registration error was measured for 170 landmarks distributed over the viscero- and neurocranium in 10 repeats per splint type using the Vector Vision2 (BrainLAB AG, Heimstetten, Germany) navigation system. Statistical and graphical evaluations were performed per anatomical region.

Results: In the periorbital region, the rapid splint, with an average deviation of 1.50 mm (SD = 0.439) showed greater accuracy than the extender with 1.76 mm (SD = 0.525). The viscerocranial results for both splints were similar (extender 1.84 mm, SD = 0.559, rapid occlusal splint 1.86 mm, SD = 0.686). In the cranial vault region, registration with the extender (2.33 mm, SD = 0.685) proved to be more precise than with the rapid splint (2.86 mm, SD = 0.929).

Conclusions: Due to the more compact dimension of the rapid occlusal splint, errors close to the splint were smaller compared to the extender technique. The advantage of greater distances between the registration fiducials on the extender is particularly important in areas such as the orbital roof, the cranial vault, and the lateral skull base.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcms.2013.05.040DOI Listing

Publication Analysis

Top Keywords

occlusal splint
16
splint
11
surgical navigation
8
rapid splint
8
rapid occlusal
8
cranial vault
8
registration
6
extender
5
evaluation dental
4
dental registration-splint
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!