In vivo dialysis setup with a loop injection valve facilitates retrodialysis studies.

J Pharmacol Toxicol Methods

Department of Psychiatry & Behavioral Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA.

Published: March 2014

Introduction: Retrodialysis, as used in neuropharmacological research, is a technique for in vivo delivery of neuroactive agents with concurrent monitoring of their effects on cellular activity with a separation between certain degree of spatial and temporal resolution. Typically, this is accomplished either by the use of a liquid-switch requiring multiple pumps, or by exchange of flow tubing requiring stopping and restarting dialysis. In the present study, we describe the use of a medium pressure injection valve for retrodialysis that overcomes these problems.

Methods: The valve was configured with a loop to deliver 20μL of solution, and artificial CSF flow from the pump to the probe was established via this device. The application of this setup was evaluated in urethane anesthetized adult male C57BL/6J mice prepared with a CMA 11 probe implanted in the ventral hippocampus. By switching between the load and inject positions, the loop was filled with escitalopram solution (0.3μM) and delivered at a rate of 1μL/min at the probe for retrodialysis. Escitalopram (2mg/kg BW) was administered subcutaneously for microdialysis studies. During these treatments, dialysate fractions were collected for the determination of serotonin (5-HT) and 5-hydroxyindoleacetic acid (5-HIAA).

Results: Irrespective of route of escitalopram administration, the pattern of dialysate 5-HT, and 5-HIAA response was comparable to that reported by other investigators. Accordingly, the in-line valve assembly did not compromise retrodialysis or microdialysis sampling. The manipulations to carry out retrodialysis using the valve setup are easy and simple.

Discussion: An in-line injection valve is a promising adaptation for retrodialysis studies and can be incorporated as a standard part of in vivo dialysis instrumentation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.vascn.2013.06.002DOI Listing

Publication Analysis

Top Keywords

injection valve
12
vivo dialysis
8
retrodialysis studies
8
retrodialysis
7
valve
6
dialysis setup
4
setup loop
4
loop injection
4
valve facilitates
4
facilitates retrodialysis
4

Similar Publications

Rationale: Warfarin is the most commonly used drug in patients with mechanical valve replacement. Acute liver damage after warfarin is rare but potentially harmful. We present a case of warfarin-induced gastrointestinal bleeding with liver injury, pharmacy monitoring, and its therapy.

View Article and Find Full Text PDF

Managing Recurrent Endocarditis in Substance Use Disorder: The Role of Civil Commitment and Comprehensive Care.

Am J Case Rep

January 2025

Department of Behavioral Medicine and Psychiatry, Rockefeller Neuroscience Institute, West Virginia University, Morgantown, WV, USA.

BACKGROUND The incidence of drug-induced infectious endocarditis is rapidly rising in the United States. Healthcare providers face different challenges in the management of infectious endocarditis in persons who inject drugs, including addiction relapse, non-compliance with treatment, and the associated social stigma. These factors collectively complicate the management of drug-induced endocarditis, requiring comprehensive strategies that address both the medical condition and the underlying substance use disorder, as well as socio-behavioral aspects of patient care.

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

The deflector jet pressure servo valve (DJPSV), a critical component of the aircraft brake servo system, requires a precise foundational model for performance analysis, optimization, and enhancement. However, the complexity of the jet process within the V-groove of the deflector plate presents challenges for accurate mathematical modeling. To address this issue, the paper takes the DJPSV as the research object, carries out detailed mathematical modeling of its components, analyzes the influencing factors of the performance of the key component-the front stage-and optimizes the design of the key factors.

View Article and Find Full Text PDF

Background And Objective: Deep vein thrombosis (DVT) of the lower limbs is a critical global vascular disease. Accurately assessing and predicting the efficacy of DVT treatment remains a significant challenge due to a lack of understanding of the mechanisms by which the level of patient-specific embolization and the rate of drug injection affect thrombolytic therapy.

Methods: In this study, we used the computed tomographic venography (CTV) clinical method to obtain patient-specific parameters, and the flow-solid interaction (FSI) method combined with biochemical response modeling of thrombolysis to analyze patient-specific hemodynamic and biomechanical characteristics and to quantitatively assess the effects of three vessel embolism levels (VEL) versus two drug injection rates (DIR) on bifurcated femoral venous thrombolytic therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!