This study introduced a simple combining apparatus for performing a magnetic stirring-assisted dispersive liquid-liquid microextraction (MSA-DLLME) for the detection of trace carbamate and organophosphorus pesticides in tea drinks coupled with high performance liquid chromatography. The simple combining apparatus was made up of a sample vial and a cut plastic dropper. The bulb end of the cut plastic dropper was inserted into the neck of the sample vial and the open tip end of the plastic dropper was then cut to an appropriate length. The combining apparatus made was then used to perform the MSA-DLLME. In this experiment, 1-octanol was injected into the tea drink sample solution and the extraction process accelerated by magnetic agitation. The sample solution turned clear and separated into two layers after leaving it alone for several minutes. The cut plastic dropper was gently put down into the sample vial, and then the liquid level of the sample solution elevated up to the tip of the plastic dropper for the collection of low-density extractant. Finally, the collected extractant was drawn out by a microsyringe and injected into the high performance liquid chromatography-diode-array detector for analysis. A series of extraction parameters were investigated and optimized. Under the most favorable conditions, high enrichment factors were obtained for carbofuran, carbaryl and isocarbophos (between 130 and 185). The limits of detection (S/N=3) were in the range of 0.13-0.61 μg L(-1), and the relative standard deviation varied below 7.8% (n=5). Additionally, good recoveries were obtained between 79.4% and 114.4% in the three tea drinks. The simple combining apparatus utilized in this MSA-DLLME method was shown to be economical, fast, and convenient for the collection of low density extractant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2013.05.033DOI Listing

Publication Analysis

Top Keywords

combining apparatus
20
plastic dropper
20
simple combining
16
tea drinks
12
sample vial
12
cut plastic
12
sample solution
12
apparatus perform
8
magnetic stirring-assisted
8
stirring-assisted dispersive
8

Similar Publications

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

Background: Many respiratory diseases such as pneumoconiosis require to close monitor the symptoms such as abnormal respiration and cough. This study introduces an automated, nonintrusive method for detecting cough events in clinical settings using a flexible chest patch with tri-axial acceleration sensors.

Methods: Twenty-five young healthy persons (hereinafter referred to as healthy adults) and twenty-five clinically diagnosed pneumoconiosis patients (hereinafter referred to as patients) participated in the experiment by wearing a flexible chest patch with an embedded ACC sensor.

View Article and Find Full Text PDF

Waterborne bacteria pose a serious hazard to human health, hence a precise detection method is required to identify them. A photonic crystal fiber sensor that takes into account the dangers of aquatic bacteria has been suggested, and its optical characteristics in the THz range have been quantitatively assessed. The PCF sensor was designed and examined as computed in Comsol Multiphysics, a program in which uses the method of "Finite Element Method" (FEM).

View Article and Find Full Text PDF

5-Methylcytosine (5mC) and 5-hydroxymethylcytosine (5hmC) are crucial epigenetic modifications in eukaryotic genomic DNA that regulate gene expression and are associated with the occurrence of various cancers. Here, we combined bisulfite conversion with 4-acetamido-2,2,6,6-tetramethyl-1-oxopiperridinium tetrafluoroborate (ACTBF, TCI) oxidation to develop a label-free and sequence-independent isothermal amplification (BTIA) assay for a genome-wide 5mC and 5hmC analysis. The BTIA strategy can distinguish 5mC and 5hmC signatures from other bases with high sensitivity and good specificity, avoiding sophisticated chemical modifications and expensive protein labeling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!