Glioblastoma multiforme (GBM) is the most common, aggressive, highly malignant and infiltrative of all brain tumors with low rate of control. The main goal of this work was to evaluate the spatial dose distribution into a GBM simulator inside a head phantom exposed to a 15 MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Such phantom holds the following synthetic structures: brain and spinal cord, skull, cervical and thoracic vertebrae, jaw, hyoid bone, laryngeal cartilages, head and neck muscles and skin. Computer tomography (CT) of the simulator was taken, capturing a set of contrasted references. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples at coronal, sagittal-anterior and sagittal-posterior positions, inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, measured at coronal section, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. And, as final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729429 | PMC |
http://dx.doi.org/10.1186/1748-717X-8-168 | DOI Listing |
Phys Med Biol
January 2025
Joint Department of Physics, The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, London, SM2 5PT, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.
The exact temporal characteristics of beam delivery affect the efficacy and outcome of ultra-high dose rate (UHDR or "FLASH") radiotherapy, mainly due to the influence of the beam pulse structure on mean dose rate. Single beams may also be delivered in separate treatment sessions to elevate mean dose rate. This paper therefore describes a model for pulse-by-pulse treatment planning and demonstrates its application by making some generic observations of the characteristics of FLASH radiotherapy with photons and protons.
View Article and Find Full Text PDFEndocrinol Diabetes Metab Case Rep
January 2025
Summary: Vitamin D is commonly recommended for daily intake as dietary sources are often insufficient. However, prolonged high-dose use can lead to serious complications. We present a rare case of a 2-month-old infant who developed severe hypercalcemia and hypertriglyceridemia due to an accidental overdose of 25-OH vitamin D, leading to hypertriglyceridemia and pancreatitis.
View Article and Find Full Text PDFPerspect Clin Res
August 2024
Department of Nephrology, Seth GS Medical College and KEM Hospital, Mumbai, Maharashtra, India.
Background: Pharmacotherapy of chronic kidney disease (CKD) consists of prescribing myriad of drugs such as antihypertensives, antidiabetics, and phosphate binders to delay disease progression and control the comorbidities, resulting in inherent variability in prescriptions. In addition, tendency to self-medicate may further aggravate the condition. Hence, the present study was planned to assess self-medication practices and variability in prescription patterns in CKD patients.
View Article and Find Full Text PDFRheumatology (Oxford)
January 2025
Nephrology Center and Department of Rheumatology, Toranomon Hospital, Tokyo, Japan.
Objectives: To evaluate the efficacy and safety of first-line targeted synthetic disease-modifying anti-rheumatic drugs (tsDMARDs) in patients with rheumatoid arthritis (RA) and chronic kidney disease (CKD).
Methods: This retrospective cohort study included 216 patients with RA prescribed their first tsDMARDs at two hospitals between 2013 and 2022. Dose reduction and contraindication guidelines for tsDMARDs according to kidney function were followed.
Am J Health Syst Pharm
January 2025
Veterans Health Care System of the Ozarks, Fayetteville, AR, USA.
Disclaimer: In an effort to expedite the publication of articles, AJHP is posting manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!