Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Context: Semen Strychni is the seed of Strychnos nux-vomica L. (Loganiaceae). Its quality control procedure remains an issue since previous reports only focused on Strychnos alkaloids. To the best of our knowledge, chlorogenic acid (a phenolic acid) and loganin (an iridoid glycoside) are selected for the first time as marker constituents of quality control for Semen Strychni because of their bioactive activity correlating with therapeutic effects.
Objective: This study aimed to develop a simple and comprehensive quantity control method for Semen Strychni.
Materials And Methods: The optimal ultrasonic extraction procedure was carried out for 45 min using 50% aqueous methanol with 1% formic acid. The satisfactory chromatographic separation was achieved on an Ultimate LP-C18 column with gradient elution using acetonitrile and water containing 30 mmol/L ammonium acetate and 1% formic acid. The high performance liquid chromatography method with diode array detector was validated for linearity, limit of detection and quantification (LOQ), precision, repeatability, accuracy and stability.
Results: All the calibration curves showed good linearity (r(2) ≥ 0.999). The LOQ values for chlorogenic acid, loganin, strychnine, brucine, strychnine N-oxide and brucine N-oxide were 0.54, 0.83, 0.48, 0.50, 0.52 and 0.54 μg/mL, respectively. The method was reproducible with good accuracy in the range 95.6-104.4% and relative standard deviation (RSD) values less than 4.55%. The method was then applied to determine the components of the seed coat, seed leaf, endosperm and whole seed of Semen Strychni.
Conclusion: This newly established method is validated as a simple and practical tool for authentication and quality control of Semen Strychni.