A wipe-sampling procedure followed by a simple liquid chromatography-mass spectrometry method was developed and validated for the simultaneous quantification of three cytotoxic drugs [5-fluorouracil (5FU), doxorubicin and cyclophosphamide (CP)] for the determination of surface contamination. After a solid-phase extraction procedure with wiping filter paper, the separation was performed within 30 min using a gradient mobile phase. The method was validated according to the recommendations of the US Food and Drug Administration. Wiping was performed using Whatman(®) filter paper on different surfaces such as stainless steel, polypropylene and glass. The method was linear, between 10 and 500 ng per wiping sample (i.e., 0.1-5 ng/cm(2)) for 5FU and doxorubicin, and between 1-100 ng per wiping sample (i.e., 0.01-1 ng/cm(2)) for CP. The lower limits of detection and quantification were 5 and 10 ng per wiping sample for 5FU and doxorubicin, and 0.5 and 1 ng per wiping sample for CP. This new sensitive methodology for surface contamination studies was successfully applied on commercial vials and different places in a cancer research hospital. This approach is particularly suitable to assess the risk of occupational exposure to cytotoxic drugs and to optimize the cleaning process, especially for the most toxic molecule studied, CP.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkt045DOI Listing

Publication Analysis

Top Keywords

wiping sample
16
surface contamination
12
5fu doxorubicin
12
wipe-sampling procedure
8
doxorubicin cyclophosphamide
8
cytotoxic drugs
8
filter paper
8
wiping
6
validated wipe-sampling
4
procedure coupled
4

Similar Publications

Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.

Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.

View Article and Find Full Text PDF

Reusing healing abutments is common practice among clinicians; however, ensuring complete surface decontamination is crucial to avoid further complications. This study aimed to evaluate the cleaning potential of Er: YAG laser at different frequencies, as an adjunctive step prior to autoclave sterilization. Forty contaminated healing abutments were divided into four groups.

View Article and Find Full Text PDF

First Report of Causing Leaf Blight on in China.

Plant Dis

December 2024

Chiang Mai University, Biology, Room 2410/00, SCB2 building, Faculty of Science, Chiang Mai University,239 Huay Kaew Road, Suthep, Muang, Chiang Mai Province, Thailand, 50200;

Peacock plant (Calathea orbifolia (Linden) H.A.Kenn.

View Article and Find Full Text PDF

Simple and rapid capillarity-assisted ultra-trace detection of thiram on apple surface with a silver nanoparticles/filter paper SERS substrate.

J Hazard Mater

December 2024

State Key Laboratory of Food Science and Resources, Jiangnan University, No. 1800 Lihu Avenue, Wuxi, Jiangsu Province 214122, China; School of Food Science and Technology, Jiangnan University, No. 1800 Lihu Avenue, Wuxi, Jiangsu Province 214122, China. Electronic address:

Thiram is a readily synthesized, cost-effective antimicrobial agent widely used to control diseases in fruits and vegetables. Given the potential health hazards associated with thiram residues and advancements in detection methods, it is crucial to develop a rapid and sensitive technique for detecting these residues on fruit surfaces. Here, we prepared the Ag@filter paper (Ag@FP) surface-enhanced Raman scattering (SERS) substrate in a controlled manner and innovatively developed a capillarity-assisted SERS (CA-SERS) detection method.

View Article and Find Full Text PDF

In the scope of the European Union (EU) human biomonitoring initiative, a multicentric study on different occupational settings from several European countries was performed, to provide information on occupational exposure to hexavalent chromium [Cr(VI)], a known lung carcinogen. Biomonitoring approaches were used to obtain exposure data to support the implementation of new risk management measures and policy actions at the national and European levels. This work describes the Portuguese contribution to the study, which aimed to assess workers' exposure to Cr, by using exposure biomarkers (urinary chromium [U-Cr]), and industrial hygiene samples (air and hand wipes) and to link exposure to potential long-term health effects by using effect biomarkers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!