Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the effect of interpupillary distance (IPD) on stereoacuity using 2 kinds of stereoacuity tests in a normal population.
Methods: The distance stereoacuities of 33 healthy volunteers with no evidence of ocular diseases were measured with the Frisby Davis distance (FD2) stereotest and a 3-dimensional monitor-based distance stereotest (distance 3-D stereotest). These 2 kinds of stereotests were repeated using horizontal periscopes to increase the IPD 2- and 3-fold in order to investigate the effect of IPD increase on stereoacuity.
Results: The mean age of the participants was 28.5 years (range 20-41 years). The mean logarithms of the individual minimum angle of stereodiscrimination (logMAS) were 1.04 ± 0.23 (range 0.70-1.48 logMAS) with the FD2 stereotest and 1.52 ± 0.19 (range 1.00-1.85 logMAS) with the distance 3-D stereotest. As the IPD increased 2- and 3-fold, the logMAS measured with the FD2 stereotest improved from 1.04 to 0.98 and 0.91 (P = 0.061 and P = 0.003), respectively, and those measured with the distance 3-D stereotest worsened from 1.52 to 1.73 and 1.85 (P < 0.001 and P < 0.001), respectively.
Conclusions: Changes in IPD measured with the FD2 stereotest exhibited opposite effects to those measured with the distance 3-D stereotest. This reflects what is known to happen in the real world, i.e., that stereoacuity improves as IPD increases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10384-013-0253-9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!