Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Group B Streptococcus (GBS; Streptococcus agalactiae) is a leading cause of serious neonatal infections. The Centers for Disease Control and Prevention recommends GBS screening for all pregnant women during the 35th to 37th weeks of gestation. Although GBS screening has been performed mainly by the culture-based method, it takes several days to obtain a reliable result. In this study, we developed a rapid immunochromatographic test (ICT) for the detection of GBS-specific surface immunogenic protein in 15 min using an overnight enrichment culture. The ICT was prepared using two anti-Sip monoclonal antibodies. This ICT was able to detect recombinant Sip levels of 0.5 ng/ml, or about 10(6) CFU/ml of GBS cells, in tests with 9 GBS strains of different serotypes. The cross-reactivity test using 26 species of microorganism showed no detectable false-positive result. Reactivity of the ICT with 229 GBS strains showed one false-negative result that was attributable to the production of truncated Sip. Among 260 enrichment cultures of vaginal swabs, 17 produced red to orange pigments in Granada medium, and they were all GBS and Sip positive. Among 219 pigment-negative cultures, 12 were GBS positive and 10 were Sip positive. Two Sip-negative cultures contained GBS cells below the limit of detection by the ICT. Among 207 GBS-negative cultures, only one was Sip positive, which was attributable to GBS cell debris. Thus, the sensitivity and specificity of the ICT appeared to be 93.1% and 99.6%, respectively. The newly developed ICT is readily applicable to clinical use in the detection of GBS.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3889584 | PMC |
http://dx.doi.org/10.1128/CVI.00171-13 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!