The aim of this study was to evaluate acoustic radiation force impulse imaging for cervical lymphadenopathy in routine clinical practice and to correlate the acoustic radiation force impulse values with the morphological signs and the pathological results, which were used as the reference standard. The virtual touch tissue quantification values were analyzed in 123 patients (mean age 40.8 years, range 1-81 years) with 181 cervical lymph nodes (87 benign, 94 malignant). The diagnostic performance of acoustic radiation force impulse values were evaluated with respect to sensitivity, specificity, and area under the curve using a receiver operating characteristic curve analysis. The mean virtual touch tissue quantification values of the benign lesions (2.01 ± 0.95 m/s) differed from that of the malignant lesions (4.61 ± 2.56 m/s; P<0.001). The cutoff level for virtual touch tissue quantification value for malignancy was estimated to be 2.595 m/s. Using the receiver operating characteristic curve curves with the cutoff value, the virtual touch tissue quantification value predicted malignancy with a sensitivity of 82.9%, specificity of 93.1% and gave an areas under the curve of 0.906 (95% CI 0.857-0.954). Acoustic radiation force impulse is feasible for cervical lymph nodes and provides quantitative elasticity measurements, which may complement B-mode ultrasound and potentially improve the characterization of cervical lymph nodes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2013.05.039DOI Listing

Publication Analysis

Top Keywords

acoustic radiation
16
radiation force
16
force impulse
16
imaging cervical
8
cervical lymph
8
lymph nodes
8
impulse values
8
virtual touch
8
touch tissue
8
tissue quantification
8

Similar Publications

A low-frequency broadband ring transducer driven by the flextensional structure.

J Acoust Soc Am

January 2025

National Key Laboratory of Underwater Acoustic Technology, Harbin Engineering University, Harbin 150001, China.

The flextensional transducer (FT) is a typical low-frequency transmitting transducer that is capable of high-power operation due to its capacity for displacement amplification. This article uses the structural configuration of the class IV FT as the basis for designing a ring transducer, which is a circular structure comprising a multitude of class IV flextensional structures as well as circular acoustic radiation structures. The flextensional structure drives the circular acoustic radiation structure, which in turn generates sound waves at low frequencies.

View Article and Find Full Text PDF

The World Health Organization Environmental Noise Guidelines provide source-based nighttime sound level (Lnight) recommendations. For non-aircraft sources, the recommended Lnight is where the absolute prevalence of high sleep disturbance (HSD) equals 3%. The Guideline Development Group did not provide an Lnight for wind turbines due to inadequate data.

View Article and Find Full Text PDF

Short-term memory for sequences of verbal items such as written words is reliably impaired by task-irrelevant background sounds, a phenomenon known as the "Irrelevant Sound Effect" (ISE). Different theoretical accounts have been proposed to explain the mechanisms underlying the ISE. Some of these assume specific interference between obligatory sound processing and phonological or serial order representations generated during task performance, whereas other posit that background sounds involuntarily divert attention away from the focal task.

View Article and Find Full Text PDF

Introduction: Individuals with hearing loss and hearing aid users report higher levels of listening effort and fatigue in daily life compared with those with normal hearing. However, there is a lack of objective measures to evaluate these experiences in real-world settings. Recent studies have found that higher sound pressure levels (SPL) and lower signal-to-noise ratios (SNR) are linked to increased heart rate and decreased heart rate variability, reflecting the greater effort required to process auditory information.

View Article and Find Full Text PDF

Radiation efficiency varying equivalent radiated power.

J Acoust Soc Am

January 2025

Grundfos A/S, Bjerringbro, 8550, Denmark.

In this paper, an improved version of the classical equivalent radiated power (ERP) approximation is proposed based on principled physical arguments. A geometry-, frequency-, and vibration pattern-dependent approximation of radiation efficiency is developed and used as a corrective factor for the classical ERP approximation. The proposed method called "radiation efficiency varying equivalent radiated power" (revERP), is shown to greatly improve the accuracy of classical ERP at low Helmholtz numbers, while attaining the accuracy of classical ERP at high Helmholtz numbers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?