  • The study extends the diffusion tensor signal model for multiple-coil acquisition systems, evaluating the noise effects on diffusion tensor (DT) estimation.
  • It utilizes the Cramér-Rao bound (CRB) to compare different gradient field setups and demonstrates that using more acquisition coils improves the estimation accuracy of fiber-type anisotropy tensors.
  • Results suggest that CRB is a useful approach for optimizing experimental designs in diffusion tensor-related research.

Article Abstract

We extend the diffusion tensor (DT) signal model for multiple-coil acquisition systems. Considering the sum-of-squares reconstruction method, we compute the Cramér-Rao bound (CRB) assuming the widely accepted noncentral chi distribution. Within this framework, we assess the effect of noise in DT estimation and other measures derived from it, as a function of the number of acquisition coils, as well as other system parameters. We show the applications of CRB in many actual problems related to DT estimation: we compare different gradient field setup schemes proposed in the literature and show how the CRB can be used to choose a convenient one; we show that for fiber-type anisotropy tensors the ellipsoidal area ratio (EAR) can be estimated with less error than other scalar factors such as the fractional anisotropy (FA) or the relative anisotropy (RA), and that for this type of anisotropy tensors, increasing the number of coils is equivalent to increasing the signal-to-noise ratio, i.e., the information of the different coils can be regarded as independent. Also, we present results showing the CRB of several parameters for actual DT-MRI data. We conclude that the CRB is a valuable tool to optimal experiment design in DT-related studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2013.04.009DOI Listing

Publication Analysis

Top Keywords

diffusion tensor
8
multiple-coil acquisition
8
acquisition systems
8
anisotropy tensors
8
crb
5
error bounds
4
bounds diffusion
4
tensor estimation
4
estimation multiple-coil
4
systems extend
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!