Effect of anterior versus posterior in situ decompression on ulnar nerve subluxation.

Am J Orthop (Belle Mead NJ)

Division of Hand Surgery, Orthopedics Department, Kaiser Permanente Medical Group, Denver, CO 80205, USA.

Published: June 2013

We sought to determine the effect anterior versus posterior in situ decompression with 360° external neurolysis on ulnar nerve subluxation. Ten cadaveric specimens were used, with anterior release performed on 5 specimens and posterior release the other 5 specimens. Each specimen was released for 4 cm centered over the cubital tunnel followed by 12 cm, 20 cm, and 20 cm with 360° external neurolysis. After release, the elbow was brought through a range of motion from 0° to 140° of flexion. Compared with posterior release, anterior release demonstrated significantly more total subluxation of the ulnar nerve for all release types from 80° to 120° of flexion (P<.05). At 140° of flexion, the 4-cm release, the 12-cm release, and the 20-cm release with 360° external neurolysis also demonstrated significantly more total subluxation with anterior release (P<.05). Ulnar nerve subluxation was significantly lower with posterior release, compared with anterior release for limited and complete in situ decompression.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ulnar nerve
12
anterior versus
8
versus posterior
8
posterior situ
8
situ decompression
8
nerve subluxation
8
360° external
8
external neurolysis
8
anterior release
8
posterior release
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!