[Determination of1-bromopropane in the workplace air by GC-FID].

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi

School of Public Health/Key Laboratory of Public Health Safety, Ministry of Education, Fudan University, Shanghai 200032, China.

Published: June 2013

Objective: To establish a method for determination 1-bromopropane (1-BP) in workplace air by gas chromatography-flame ionization detector (GC-FID).

Method: 1-bromopropane in workplace air was collected with activated charcoal tube, then desorbed by carbon disulfide and determined by GC-FID. 1-bromopropane was quantitatively measured using retention time and peak area.

Results: Linear regression formula was Y = 3353.4x-10064 in a range of 2.50 ∼ 500.00 µg/ml with regression coefficient R = 0.9998. Detection limit was 0.25 µg/ml and the lowest detection concentration of 1-brmopropane in air was 0.14 mg/m(3) (at air volume 1.8L). The mean recoveries of 1-BP were between 96.8% and 102.6%, and relative standard deviation of inter and intra-assay was less than 10%. The average desorption efficiencies were between 93.2% and 104.4%. The samples in activated charcoal tube could be stably stored for 5 days at room temperature.

Conclusion: The method could be feasible to determine 1-bromopropane in workplace air.

Download full-text PDF

Source

Publication Analysis

Top Keywords

workplace air
16
1-bromopropane workplace
8
activated charcoal
8
charcoal tube
8
air
6
[determination of1-bromopropane
4
workplace
4
of1-bromopropane workplace
4
air gc-fid]
4
gc-fid] objective
4

Similar Publications

: The aim is to bring attention to the existence of a rare type of trauma of the hand, high-pressure injection injury, that appears to be minor with negligible signs and symptoms within the first hours after the accident, but in reality, produces significant tissue destruction with severe consequences. Recognizing this type of trauma by medical personnel, understanding the mechanisms involved, and knowing the etiological and prognostic factors can lead to early treatment initiation and avoid severe mutilating sequelae. : A retrospective study on 16 patients diagnosed with high-pressure injection injuries, including water, air, paint, paint mixed paint with thinner, petroleum jelly, and lime (washable paint containing calcium oxide).

View Article and Find Full Text PDF

Revealing Stachybotrys-like fungal growth in buildings - Possible exposure highlighted through three case studies.

Sci Total Environ

January 2025

Department of Civil Engineering, Aalto University, 00076 Espoo, Finland; International Laboratory for Air Quality and Health, Faculty of Science, School of Earth & Atmospheric Sciences, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia. Electronic address:

Genus Stachybotrys (Stachybotryaceae, Hypocreales) requires high humidity to grow and represents one of the most notorious fungi associated with suspected illness in moist buildings. If Stachybotrys conidia are found in settled indoor dusts, their presence may indicate water intrusion and mold infestation revealed after dismantling the building structures. This study describes detection of Stachybotrys growth hidden inside the structures of three buildings in Finland.

View Article and Find Full Text PDF

Since 2011, Caribbean territories have experienced massive and repeated sargassum seaweed inundations. Once on shore, sargassum degradation through anaerobic metabolism elicits the release of many noxious molecules, including hydrogen sulfide (HS) and ammonia (NH). HS has been long recognized as a malodorous and highly toxic gas, while chronic exposure has not been extensively explored.

View Article and Find Full Text PDF

Microbial volatile organic compounds measured in the air of a waste sorting plant and a university by thermal desorption-gas chromatography-tandem mass spectrometry.

Environ Monit Assess

January 2025

Institut de Recherche Robert-Sauvé en Santé Et en Sécurité du Travail (IRSST), Montréal, Québec, Canada.

Article Synopsis
  • In recyclable waste management facilities, bioaerosols and microorganisms may be released, posing health risks, with a focus on microbial volatile organic compounds (mVOCs) as potential mold exposure biomarkers.
  • A study compared mVOC concentrations between a recyclable waste sorting plant (WSP) and a university campus (UC), finding 13 mVOCs at WSP versus only 3 at UC, emphasizing the higher levels of contamination at WSP.
  • The research optimized mVOC sampling methods, revealing distinct profiles of mVOCs in contaminated versus non-contaminated environments and identifying specific mVOCs that serve well as biomarkers for mold exposure.
View Article and Find Full Text PDF

Objective: assessment of probable exposure levels from radon and NORM in workplaces within the context of justi fying radiation protection plans in an existing exposure situation.

Materials And Methods: Materials regarding the assessment of naturally occurring radioactive material (NORM) con tent in tailing from mining and processing industries in Ukraine and assessments of contamination levels of industri al sites of oil and gas enterprises were used for estimating the probable range of effective doses (ED) of workers fromNORM at industrial enterprises. These materials were obtained as a result of research conducted by specialists from theRadiation Protection Laboratory of the State Institution «O.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!