A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel 3-dimensional motion analysis method for measuring the lumbar spine range of motion: repeatability and reliability compared with an electrogoniometer. | LitMetric

Novel 3-dimensional motion analysis method for measuring the lumbar spine range of motion: repeatability and reliability compared with an electrogoniometer.

Spine (Phila Pa 1976)

*Department of Rehabilitation Medicine, The University of Tokyo, Tokyo, Japan †Department of Rehabilitation Medicine, The University of Tokyo Hospital, Japan ‡Department of Sensory-Recognition and Locomotive-Function Sciences in the Super-Aged Society, The University of Tokyo, Tokyo, Japan; and §Department of Medical Engineering, The University of Tokyo Hospital, Tokyo, Japan.

Published: October 2013

Study Design: Repeatability and reliability for measuring methods for real-time lumbar range of motion.

Objective: We established a novel set of marker positions for 3-dimensional motion analysis (VICON system) to determine lumbar spine range of motion (LROM) and lumbar motion precisely; we compared the repeatability and reliability of VICON system with those of an electrogoniometer.

Summary Of Background Data: The assessment of the LROM using x-ray is still one of the most precise methods, despite the radiation exposure. To avoid this, alternative methods, such as the VICON system and electrogoniometer, have been widely used. No study has reported the repeatability and reliability of LROM measurements using a VICON system and electrogoniometer.

Methods: The VICON system and electrogoniometer measured LROM and lumbar motion in 7 healthy males during 7 days. Differences between both systems were analyzed using Bland-Altman plots. Repeatability and reliability of the LROM measurements was assessed using coefficients of multiple correlations and intraclass correlation coefficients, respectively. Standard error of measurement was calculated to quantify the systematic error in LROM measurements.

Results: The mean maximum LROM values using the VICON system/electrogoniometer were 42°/52° for flexion, 17°/24° for extension, 16°/16° for lateral bending, and 8°/2° for axial rotation, respectively. Between VICON system and the electrogoniometer, Bland-Altman plots revealed no discrepancies in LROM values except for flexion.Coefficients of multiple correlations for LROM showed excellent repeatability. LROM measurements with VICON system showed excellent reliability for flexion and extension and fair-to-good reliability for other motions. LROM measurements with the electrogoniometer showed excellent reliability for flexion and fair-to-good reliability for other motions. Except for axial rotation, maximum intraclass correlation coefficients using VICON system were more reliable than the electrogoniometer for measuring lumbar motion.

Conclusion: VICON system with our novel marker set allows practical and reliable longitudinal assessment of dynamic LROM.

Level Of Evidence: N/A.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e3182a0dbc5DOI Listing

Publication Analysis

Top Keywords

vicon system
36
repeatability reliability
20
lrom measurements
16
system electrogoniometer
12
lrom
11
vicon
10
reliability
9
system
9
3-dimensional motion
8
motion analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!