Purpose: To study the feasibility of a novel endorectal electrode for the creation of focal ablations of the rectal wall with the use of irreversible electroporation (IRE).

Materials And Methods: A monopolar electrode with a grounding pad (10 ablations in five pigs) and a bipolar electrode (two ablations in one pig) were evaluated in healthy swine rectum. A two-dimensional model of the electrode in the rectum was created and used to solve the Laplace equation to determine field strength. Simulation was used to identify treatment settings for superficial ablation (mucosal layers) or transmural ablation of rectal wall. Animals were euthanized within 4 hours after treatment.

Results: Treatment was successfully completed without treatment-related complications. Eleven of 12 lesions were successfully located and extracted for pathologic analysis. All lesions were characterized by necrotic cell death with mild inflammation and hyperemia, with a sharp demarcation between ablated and adjacent normal tissue. Depth of lesions corresponded with numeric simulation. Histologic analysis and measurements indicated that lesion creation with the superficial treatment setting resulted in ablation of mucosal and submucosal layers with superficial or no injury to the muscularis propria (9.97 mm ± 0.31 length, 3.3 mm ± 2.92 depth), and that lesion creation with the transmural treatment setting resulted in full-thickness ablation (12.43 mm ± 3.85 length, 4.97 mm ± 2.89 depth) of the rectal wall.

Conclusions: An endorectal electrode can be used to deliver IRE and create limited focal ablations in the rectal wall. Treatment parameters can be determined through numeric modeling to control the depth of penetration of ablation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2013.04.025DOI Listing

Publication Analysis

Top Keywords

endorectal electrode
12
rectal wall
12
irreversible electroporation
8
swine rectum
8
focal ablations
8
ablations rectal
8
ablation mucosal
8
lesion creation
8
treatment setting
8
electrode
6

Similar Publications

Objective: The purpose of this study is to report the patient safety and image quality of 1.5-T multiparametric MRI of the prostate in patients with cardiac implantable electronic devices (CIEDs).

Materials And Methods: In this retrospective study, a database was searched to identify prostate multiparametric 1.

View Article and Find Full Text PDF

Purpose: To study the feasibility of a novel endorectal electrode for the creation of focal ablations of the rectal wall with the use of irreversible electroporation (IRE).

Materials And Methods: A monopolar electrode with a grounding pad (10 ablations in five pigs) and a bipolar electrode (two ablations in one pig) were evaluated in healthy swine rectum. A two-dimensional model of the electrode in the rectum was created and used to solve the Laplace equation to determine field strength.

View Article and Find Full Text PDF

Current prostate biopsy procedures entail sampling tissues at template-based locations that are not patient specific. Ultrasound (US)-coupled transrectal electrical impedance tomography (TREIT), featuring an endorectal US probe retrofitted with electrodes, has been developed for prostate imaging. This multi-modal imaging system aims to identify suspicious tumor regions based on their electrical properties and ultimately provide additional patient-specific locations where to take biopsy samples.

View Article and Find Full Text PDF

In 2009, prostate cancer ranked as the most common cancer and the second most fatal cancer in men in the United States. Unfortunately, the current clinical diagnostic methods (e.g.

View Article and Find Full Text PDF

Prostate cancer: MR imaging-guided galvanotherapy--technical development and first clinical results.

Radiology

December 2007

Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Johann Wolfgang Goethe-University, Theodor-Stern Kai 7, D-60590 Frankfurt am Main, Germany.

Purpose: To prospectively evaluate the safety and effectiveness of magnetic resonance (MR) imaging-guided galvanotherapy in prostate cancer.

Materials And Methods: This prospective study was approved and authorized by the institutional review board, and patients gave informed consent. Forty-four men (mean age, 63.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!