Phase transformation behavior and mechanical properties of thermomechanically treated K3XF nickel-titanium instruments.

J Endod

Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada.

Published: July 2013

Introduction: The bending and torsional properties of thermomechanically treated K3XF (SybronEndo, Orange, CA) nickel-titanium instruments in relation to their phase transformation behavior were evaluated.

Methods: NiTi instruments K3 (SybronEndo) and K3XF, both in sizes 25/.04 and 40/.04, were examined by differential scanning calorimetry and X-ray diffraction. The metal composition was determined by scanning electron microscopy with X-ray energy-dispersive spectrometric analyses. The bending property of K3 and K3XF instruments was measured in a cantilever-bending test with a maximum deflection of 4.00 mm. A torsional test of the instruments was evaluated according to the American National Standards Institute/American Dental Association Specification No. 28.

Results: K3 and K3XF instruments had approximately the same chemical composition with a nickel content of 48-49 atomic %. The differential scanning calorimetry analyses showed that each segment of the K3XF instruments (24.89°C ± 1.98°C) had a higher austenite finish temperature than the K3 instruments (17.63°C ± 1.76°C) (P < .05). The bending load values were significantly lower for K3XF than for K3 in the superelastic ranges (P < .05). There was no statistically significant difference between K3 and K3XF in the maximum torque or maximum angular deflection before failure. The torque at fracture values of K3 and K3XF increased significantly with the diameter (P < .05).

Conclusions: K3XF exhibited different phase transformation behavior and flexibility when compared with K3, which may be attributed to the special heat treatment history of K3XF instruments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2013.04.004DOI Listing

Publication Analysis

Top Keywords

k3xf instruments
16
phase transformation
12
transformation behavior
12
k3xf
11
instruments
9
properties thermomechanically
8
thermomechanically treated
8
treated k3xf
8
nickel-titanium instruments
8
differential scanning
8

Similar Publications

This study aims to compare the cyclic fatigue resistance of nickel-titanium (NiTi) endodontic instruments, focusing on the impact of various alloy treatments and manufacturing processes across different generations of these instruments; Twenty instrumentation systems from different generations, comprising both continuous and reciprocating motion designs, were tested. Four hundred instruments underwent cyclic fatigue testing using an INSTRON machine, with the time and number of cycles to fracture (NCF) recorded for each instrument. Statistical analyses were performed to compare the fatigue resistance between systems, generations, and motion types; Instruments treated with advanced thermal processing, such as Excalibur, Reciproc Blue, and TruNatomy, demonstrated superior resistance to fracture, whereas systems like Protaper Universal, K3XF, and 2Shape showed the lowest resistance.

View Article and Find Full Text PDF

Aim: To compare the effect of different tapers of the K3XF file system on the fracture resistance of endodontically treated mandibular premolars obturated with a three-dimensional (3-D) obturation system.

Methodology: For the study, 80 freshly extracted human mandibular premolars with single well-developed roots without any curvatures were taken and the tooth roots were wrapped in a single layer of aluminum foil, and they were placed vertically in a plastic mold filled with self-curing acrylic resin. The access was opened, and working lengths were determined.

View Article and Find Full Text PDF

Aim: The objective of this study was to assess the effect of different endodontic instrumentation systems on the amount of apically extruded bacteria.

Materials And Methods: One hundred and twenty freshly extracted human mandibular premolars with single canal were collected. Endodontic access cavities were prepared and then contaminated with an suspension (ATCC 29212).

View Article and Find Full Text PDF

The present study aimed to evaluate the impact of continuous irrigation with saline solution at room temperature or +4°C on the cyclic fatigue resistance of K3XF files. Forty-eight new K3XF files (#30, .04 taper) were randomly assigned to three groups: control group (no irrigation), continuous irrigation with saline solution at room temperature, and continuous irrigation with saline solution at +4°C.

View Article and Find Full Text PDF

This study compared the amount of apically extruded debris associated with different heat-treated Ni-Ti rotary systems during the preparation of curved root canals of mandibular molars. Sixty extracted human mandibular molars were selected. EdgeFile, K3XF, OneCurve (OC) and ROTATE files were used to prepare both mesial canals of teeth.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!